Chapter 3 Introduction

The emulation's response to several of the control codes depends on the configuration. For example, upon receipt of the carriage return control code, the emulation will either perform a carriage return function only, or a carriage return and line feed, based on the configuration for the CR function.

P-Series XQ Default Values and States

The factory settings for the P-Series XQ emulation menu options are shown in Table 12. Table 12 also lists additional factory settings for parameters provided by the ASCII Emulation formatting menus. (The EMULATION menu options are described in the User’s Guide). Host control codes can override many of the settings for these menu options

Table 12. P-Series Default Settings

Characteristic

Default Setting

 

 

 

 

Select CPI

10.0 CPI

Select LPI

6.0 LPI

Typeface

Letter Gothic

Horizontal DPI

120 DPI

Vertical DPI

72 DPI

Prop. Spacing

Enable

Italic Print

Disable

Slashed Zero

Disable

Left Margin

0 characters

Right Margin

0 characters

Top Margin

0 linespaces

Bottom Margin

0 linespaces

Print Char. Set

 

Define CR code

CR = CR

Auto LF

Disable

Define LF code

LF = CR + LF

*Advanced User:

 

Control Code 06

8.0 LPI

Compressed Print

Char 01 SOH

Bold

Disable

Elong/Alt. Font

Elng=BS Font=SO

 

 

60

Page 60
Image 60
IBM 4400 manual Series XQ Default Values and States, Introduction