IBM DCS9550 1S1 SCM I/O Module LEDs, Audible Alarm Mute, Definition, Color, Normal, Fault

Models: DCS9550 1S1

1 79
Download 79 pages 24.28 Kb
Page 56
Image 56

Troubleshooting and Problem Solving

4.3.3SCM I/O Module LEDs

The SCM I/O module LEDs are shown in Table 4–3.

Table 4–3SCM I/O Module LEDs

LED

Definition

Color

Normal

Fault

 

 

 

Status

Status

 

 

 

 

 

FC Host Port 0

Incoming FC signal is GOOD

Green

On

 

Signal Good

No connection or incorrect connection

 

 

Off

 

Invalid SFP connection

 

 

Flashin

 

 

 

 

g

 

 

 

 

 

FC Host Port 1

Incoming FC signal is GOOD

Green

On

 

Signal Good

No connection or incorrect connection

 

 

Off

 

Invalid SFP connection

 

 

Flashin

 

 

 

 

g

 

 

 

 

 

Router Status

Storage Router Device Ready

Green

On

 

 

Storage Router Device not ready or

 

 

Off

 

defective

 

 

 

 

 

 

 

 

ESI/SCM

Fault present (also On when booting)

Amber

On

 

Module Fault

Successful controller initialization

 

 

Off

 

 

 

 

 

4.4Audible Alarm

The Ops Panel also includes an Audible Alarm which indicates when a fault state is present. The following conditions will activate the Audible Alarm:

Drive Fault

Fan Fault

Voltage out of range

Thermal overrun

System fault

4.4.1Audible Alarm Mute

When the Audible Alarm sounds, it may be muted by pressing the Alarm Mute push-button. Automatic muting will take place after two minutes if the mute switch is not manually operated. The Alarm Mute push-button is located above the indicators on the Ops Panel (see Figure 4–1). When the alarm is muted, it will continue to sound with short intermittent bleeps to indicate that a problem still exists. It will be silenced when all problems are cleared. (See also Thermal Shutdown states, Section 4.5.5).

LED Test Mode

The Alarm Mute push-button can also be used to test the LEDs on the Ops Panel. When the Mute push-button is held, all LEDs will be illuminated if there are no faults present.

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

41

Page 56
Image 56
IBM DCS9550 1S1 manual SCM I/O Module LEDs, Audible Alarm Mute, Definition, Color, Normal, LED Test Mode, Fault, Status