Troubleshooting and Problem Solving
4.5.3Thermal Control
The DCS9550 1S1 Storage Expansion Unit uses extensive thermal monitoring and takes a number of actions to ensure component temperatures are kept low and also to minimize acoustic noise. Air flow is from front to rear of the enclosure.
Symptom | Cause | Action | ||
|
|
|
| |
If the ambient air is | The first stage in the | 1 | Check the installation for any airflow | |
cool (below 25 °C) and | thermal control process |
| restrictions at either the front or rear | |
the fans are observed | is for the fans to |
| of the enclosure. A minimum gap of | |
to increase in speed | automatically increase |
| 25mm at the front and 50mm at the | |
then some restriction | in speed when a |
| rear is recommended. | |
on airflow may be | thermal threshold is | 2 | Check for restrictions due to dust | |
causing additional | reached. This may be | |||
internal temperature | caused by higher |
| ||
|
| |||
rise. | ambient temperatures | 3 | Check for excessive | |
Note: This is not a fault | in the local environment | |||
| heated air from rear to the front, use | |||
condition. | and may be perfectly |
| ||
| in a fully enclosed rack installation is | |||
| normal. |
| ||
|
| not recommended. | ||
| Note: This threshold |
| ||
|
|
| ||
| changes according to | 4 | Check that all Blank modules are in | |
| the number of drives |
| place. | |
| and power supplies |
|
| |
| fitted. | 5 | Reduce the ambient temperature. | |
|
|
|
|
IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide | 43 |