Introduction

Table 1–1

Ops Panel Switch Functions (Default settings for DCS9550 1S1 Storage Expansion

UnitSCM usage at 2Gb/s)

 

 

 

 

 

 

 

 

 

Switch Number

Function

Recommended Setting

Definition

*See Sw 11

 

 

 

 

 

 

 

 

 

 

 

 

 

7 & 8

 

Drive Loop Speed

Sw 7

 

Sw 8

 

 

Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCS9550 Controller Settings

Off

 

Off

Force 1Gb/s

 

 

 

 

 

 

DCS9550 Controller Settings

On

 

Off

Force 2Gb/s (recommended)

 

 

 

 

 

 

 

9 & 10

 

Drive Addressing

Sw 9

 

Sw 10

 

 

Mode Selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCS9550 Controller Settings

Off

 

On

Mode 1

 

 

 

 

 

 

 

 

 

 

On

 

On

Mode 0

 

 

 

 

 

 

 

 

 

 

On

 

Off

Mode 2

 

 

 

 

 

 

 

 

 

 

Off

 

Off

Mode 3 (not supported)*

 

 

 

 

 

 

 

11

 

SOFT SELECT

 

On

Selects functions using the

 

 

 

 

 

hardware switches

 

 

 

 

 

 

 

 

 

 

 

 

12

 

Not Used

 

Off

 

 

 

 

 

 

 

 

Note: * Please contact your supplier for further information.

Important Switch settings are only read at Power On.

1.2.3SCM Input/Output Module

The DCS9550 1S1 Storage Expansion Unit includes an enclosure with rear facing bays which houses one or two SATA Control Interface Adaptor (SCM I/O) modules (see Figure 1–3), dependent on configuration required.

The plug-in SCM I/O modules have been designed for integration into a DCS9550 1S1 Storage Expansion Unit, providing external FCAL cable interfacing with up to 16 SATA disk drives.

Processors housed on the SCM I/O modules provide enclosure management and interface to devices on the Backplane, PSU, SCM and Ops Panel, to monitor internal functions.

The module incorporates the following LED indicators:

Host

Important If only one SCM module is fitted, the SCM module must be installed in Rear Bay 4 location [see Figure 1–3, ”Enclosure Chassis (Rear)”, on page 2] and a Blank I/O module fitted in the unused

bay.

 

 

 

 

 

Table 1–2

SCM I/O Module LEDs

 

 

 

 

 

 

 

 

 

LED

 

Definition

Color

Normal

Fault

 

 

 

 

Status

Status

 

 

 

 

 

FC Host Port 0

Incoming FC signal is GOOD

Green

 

Off

Signal Good

 

No connection or incorrect connection

 

On

 

 

Invalid SFP connection

 

Flashing

 

 

 

 

 

 

 

 

 

 

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

5

Page 20
Image 20
IBM DCS9550 1S1 manual SCM Input/Output Module, DCS9550 Controller Settings