IBM T400S, T410SI manual Checking the backup battery

Models: T410SI T410S T400S

1 206
Download 206 pages 5.76 Kb
Page 49
Image 49
Checking the backup battery

Terminal

Voltage (V dc)

 

 

1

+ 0 to + 12.6

 

 

7

Ground (-)

 

 

3.If the voltage is less than +11.0 V dc, the battery pack has been discharged.

Note: Recharging will take at least 3 hours, even if the indicator does not turn on. If the voltage is still less than +11.0 V dc after recharging, replace the battery.

4.If the voltage is more than +11.0 V dc, measure the resistance between battery terminals 5 and 7. The resistance must be 4 to 30 K Ω. If the resistance is not correct, replace the battery pack. If the resistance is correct, replace the system board.

Checking the backup battery

Do the following:

1.Power off the computer, and unplug the ac adapter from it.

2.Turn the computer upside down.

3.Remove the battery pack (see “1010 Battery pack” on page 75).

4.Remove the backup battery (see “1080 Backup battery” on page 89).

5.Measure the voltage of the backup battery. See the following figure.

Wire

Voltage (V dc)

 

 

Red

+2.5 to +3.2

 

 

Black

Ground

 

 

If the voltage is correct, replace the system board.

If the voltage is not correct, replace the backup battery.

If the backup battery discharges quickly after replacement, replace the system board.

Chapter 3. General checkout 43