IBM T410SI, T400S manual Beep symptoms, Error messages continued

Models: T410SI T410S T400S

1 206
Download 206 pages 5.76 Kb
Page 62
Image 62

Table 3. Error messages (continued)

Symptom or error

FRU or action, in sequence

 

 

 

Invalid system configuration data.

1.

DIMM.

 

 

2.

System board.

 

 

 

I/O device IRQ conflict.

1.

Load “Setup Defaults” in the BIOS Setup Utility.

 

 

2.

Backup battery.

 

3.

System board.

 

 

 

Hibernation error.

1.

Restore the system configuration to what it was

 

 

 

before the computer entered hibernation mode.

 

2.

If memory size has been changed, re-create the

 

 

hibernation file.

 

 

 

Fan error.

1.

Fan.

 

 

2.

Thermal grease.

 

3.

System board.

 

 

Thermal sensing error.

System board.

 

 

Cannot boot from any device.

Check the status of device which you want to boot

 

from.

 

Device not found.

 

1.

The device you want to boot from.

 

2.

System board.

 

Device Error.

 

1.

The device you want to boot from.

 

2.

System board.

 

No valid operating system.

 

1.

Check that the operating system has no failure and is

 

 

installed correctly.

 

2.

Reinstall the operation system.

 

Excluded from boot order.

 

• Enter the BIOS Setup Utility and add the device in boot

 

order.

 

 

 

Beep symptoms

Table 4. Beep symptoms

Symptom or error

FRU or action, in sequence

 

 

 

One beep and a blank, unreadable, or flashing LCD.

1.

Reseat the LCD connector.

 

 

2.

LCD assembly.

 

3.

External CRT.

 

4.

System board.

 

 

 

56Hardware Maintenance Manual