Table 2. Numeric error codes (continued)
Symptom or error | FRU or action, in sequence | |
|
|
|
2102 | 1. | Reseat the hard disk drive. |
Initialization error on HDD1 (Ultrabay hard disk drive) | 2. | Ultrabay hard disk drive. |
| 3. | System board. |
|
|
|
2110 | 1. | Reseat the hard disk drive. |
Read error on HDD0 (Main hard disk drive) | 2. | Main hard disk drive. |
| 3. | System board. |
|
|
|
2112 | 1. | Reseat the hard disk drive. |
Read error on HDD1 (Ultrabay hard disk drive) | 2. | Ultrabay hard disk drive. |
| 3. | System board. |
|
|
|
Error messages
Table 3. Error messages
Symptom or error | FRU or action, in sequence | |
|
| |
Device address conflict. | 1. Load “Setup Defaults” in the ThinkPad Setup | |
|
| program. |
| 2. | Backup battery. |
| 3. | System board. |
|
|
|
Allocation error for device. | 1. | Load “Setup Defaults” in the ThinkPad Setup |
|
| program. |
| 2. | Backup battery. |
| 3. | System board. |
|
|
|
Failing bits: nnnn. | 1. | DIMM. |
| 2. | System board. |
|
|
|
Invalid system configuration data. | 1. | DIMM. |
| 2. | System board. |
|
|
|
I/O device IRQ conflict. | 1. | Load “Setup Defaults” in the ThinkPad Setup |
|
| program. |
| 2. | Backup battery. |
| 3. | System board. |
|
|
|
Hibernation error. | 1. | Restore the system configuration to what it was |
|
| before the computer entered hibernation mode. |
| 2. | If memory size has been changed, |
|
| hibernation file. |
|
|
|
Fan error. | 1. | Fan. |
| 2. | Thermal grease. |
| 3. | System board. |
|
| |
Thermal sensing error. | System board. | |
|
|
|
Chapter 4. Related service information 47