Table 2. Numeric error codes (continued)

Symptom or error

FRU or action, in sequence

 

 

 

2102

1.

Reseat the hard disk drive.

Initialization error on HDD1 (Ultrabay hard disk drive)

2.

Ultrabay hard disk drive.

 

3.

System board.

 

 

 

2110

1.

Reseat the hard disk drive.

Read error on HDD0 (Main hard disk drive)

2.

Main hard disk drive.

 

3.

System board.

 

 

 

2112

1.

Reseat the hard disk drive.

Read error on HDD1 (Ultrabay hard disk drive)

2.

Ultrabay hard disk drive.

 

3.

System board.

 

 

 

Error messages

Table 3. Error messages

Symptom or error

FRU or action, in sequence

 

 

Device address conflict.

1. Load “Setup Defaults” in the ThinkPad Setup

 

 

program.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Allocation error for device.

1.

Load “Setup Defaults” in the ThinkPad Setup

 

 

program.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Failing bits: nnnn.

1.

DIMM.

 

2.

System board.

 

 

 

Invalid system configuration data.

1.

DIMM.

 

2.

System board.

 

 

 

I/O device IRQ conflict.

1.

Load “Setup Defaults” in the ThinkPad Setup

 

 

program.

 

2.

Backup battery.

 

3.

System board.

 

 

 

Hibernation error.

1.

Restore the system configuration to what it was

 

 

before the computer entered hibernation mode.

 

2.

If memory size has been changed, re-create the

 

 

hibernation file.

 

 

 

Fan error.

1.

Fan.

 

2.

Thermal grease.

 

3.

System board.

 

 

Thermal sensing error.

System board.

 

 

 

Chapter 4. Related service information 47

Page 53
Image 53
IBM X220I manual Error messages