From connecting block

Operating components not reached by the remote controller signals (IR IN)

In order to use the remote controller to control the DTR-6.4/5.4 from a remote location, you will need to prepare a multi-room kit (sold separately) such as one of those given below:

Onkyo’s Multi-Room System kit (IR Remote Controller Extension System)

Multiroom A/V distribution and control system such as those from Niles® and Xantech®

If the remote controller signal does not reach the DTR-6.4/5.4 remote sensor

If the DTR-6.4/5.4 is located inside a cabinet or other enclosure where the infrared rays from the remote controller cannot enter, then operation with the remote controller will not be possible. In such a case, it will be necessary to install a remote sensor at a location outside of the cabinet where the infrared rays from the controller can reach.

With this connection, select “Main” at “Hardware Config” “IR IN Position” (see page 32).

Make the connections as shown below. Do not plug in any equipment to the power outlet until all the connections are complete.

From connecting block

Mini plug cable Manual background

RManual background

REMOTE CONTROL

MONITOR IR

OUTOUT

V

IN

S Manual background

DTR-6.4/5.4

If the remote controller signal does not reach other components

Connecting

block

IR IN

DTR-6.4/ 5.4

IR Receiver

In this situation, you will need to use a commercially available IR emitter. Connect the mini plug of the IR emitter to the IR OUT terminal on the DTR-6.4/5.4 and then place the IR emitter on the remote sensor of the component or facing it. When the IR emitter is connected, only the signal input to the IR IN terminal is output to the IR OUT terminal. The signal input from the remote sensor on the front of the DTR-6.4/5.4 will not be output to the IR OUT terminal.

Remote Controller

In the cabinet

Manual background : Signal flow

IR IN

Connecting block

IR Receiver

The IR IN input allows you to control the DTR-6.4/5.4 from the remote zone (Zone 2) with the remote controller even though the remote zone may be on the other side of the building from the main zone. The diagram below shows how to make the proper connections for the remote zone.

IR OUT Manual background

Manual background DTR-6.4/5.4

IR Emitter

Remote Controller

With this connection, select “Zone 2” at “Hardware Config” “IR IN Position” (see page 32).

IR IN

IR Receiver

DTR-6.4/5.4

Connecting block

Remote Controller

Main room

Zone 2 room

Manual background : Signal flow

other component

Manual background : Signal flow

other component

: Signal flow

Remote control

 

 

 

 

sensor

 

 

Emitter

IR

Mini plug

 

OUT

Mini plug cable

 

 

IN

 

 

 

 

IR Emitter

DTR-6.4/5.4

 

27

Page 27
Image 27
Integra DTR-6.4/5.4 instruction manual From connecting block Mini plug cable