Intel 7xx Servers, 170 Servers, AS/400 RISC Server manual 14.1.5.1

Models: 7xx Servers 170 Servers AS/400 RISC Server

1 368
Download 368 pages 6.76 Kb
Page 197
Image 197

14.1.5Comparing Current 2780/574F with the new 571E/574F and 571F/575B NOTE: iV5R3 has support for the features in this section but all of our performance measurements were done on iV5R4 systems. For information on the supported features see the IBM Product Announcement Letters.

A model 570 4 way system with 48 GB of mainstore memory was used for the following. In comparing the new 571E/574F and 571F/575B with the current 2780/574F IOA, the larger read and write cache available on the new IOA’s can have a very positive effect on workloads. Remember this workload is used to get a general comparison between new and current hardware and cannot predict what will happen with all workloads.

Also note the 571E/574F requires the auxiliary cache card to turn on RAID and the 571F/575B has the function included in its double-wide card packaging for better system protection. Understanding of the general results are intended to help customers gauge what might happen in their environments.

 

 

 

2780/571E/571F 15 DASD RAID5

 

14.1.5.1

(sec)

 

2780/574F (15 DASD): IOP, RAID-5

 

 

571E/574F (15 DASD): IOPLess, RAID-5

 

 

 

571F/575B (15 DASD): IOPLess, RAID-5

 

 

Time

 

 

 

0.2

 

 

 

 

 

0.15

 

 

 

 

 

Response

 

 

 

 

 

0.1

 

 

 

 

 

0.05

 

 

 

 

 

System

0

 

 

 

 

 

0

2500

5000

7500

10000

 

 

 

Workload Throughput

 

 

 

(ms)

 

2780/571E/571F 15 DASD RAID5

 

 

 

2780/574F (15 DASD): IOP, RAID-5

 

 

 

571E/574F (15 DASD): IOPLess, RAID-5

 

 

Time

40

571F/575B (15 DASD): IOPLess, RAID-5

 

 

 

 

 

 

14.1.5.2

Response

30

 

 

 

 

 

20

 

 

 

 

 

10

 

 

 

 

 

DASD

0

 

 

 

 

 

0

1,000

2,000

3,000

4,000

 

 

 

Ops/Sec

 

 

IBM i 6.1 Performance Capabilities Reference - January/April/October 2008

 

 

 

© Copyright IBM Corp. 2008

Chapter 14 DASD Performance

197