Intel 7xx Servers 16.8 5XX IPL Performance Measurements Normal, Normal IPL Power-On Cold Start

Models: 7xx Servers 170 Servers AS/400 RISC Server

1 368
Download 368 pages 6.76 Kb
Page 278
Image 278

16.8 5XX IPL Performance Measurements (Normal)

The following tables provide a comparison summary of the measured performance data for a normal and abnormal IPL. Results provided do not represent any particular customer environment.

Measurement units are in minutes and seconds

Table 16.8.1 Normal IPL - Power-On (Cold Start)

 

 

 

 

 

V5R3

iV5R4

 

V5R3

iV5R4

V5R3

iV5R4

 

GA3 Firmware

GA7 Firmware

 

GA3 Firmware

GA7 Firmware

GA3 Firmware

GA7 Firmware

 

2 Way

2 Way

 

16 Way

16 Way

32 Way

32 Way

 

520

520

 

570

570

595

595

 

7457

7457

 

7476

7476

7499

7499

 

16 GB

16 GB

 

256 GB

256 GB

384 GB MS

384 GB

 

23 DASD

23 DASD

 

924 DASD

924 DASD

1125 DASD

1125 DASD

Hardware

5:19

3:30

 

18:37

17:44

25:50

26:27

SLIC

3:49

4:30

 

6:42

6:43

8:50

9:36

OS/400

1:00

:50

 

1:32

2:32

2:30

3:43

Total

10:08

8:50

 

26:51

26:59

37:10

39:46

The workloads were increased for iV5R4 to better reflect common system load affecting the OS/400 portion of the IPL

Generally, the hardware phase is composed of C1xx xxxx, C3xx xxxx and C7xx xxxx on the 5xx systems. SLIC is composed of C200 xxxx and C600 xxxx. OS/400 is composed of C900 xxxx SRCs to the IBM i operating system console sign-on.

16.9 5XX IPL Performance Measurements (Abnormal)

 

 

Measurement units are in hours, minutes and seconds.

 

 

 

Table 16.9.1 Abnormal IPL (Partition MSD)

 

 

 

 

 

V5R3

iV5R4

V5R3

iV5R4

V5R3

iV5R4

 

GA3 Firmware

GA7 Firmware

GA3 Firmware

GA7 Firmware

GA3 Firmware

GA7 Firmware

 

2 Way

2 Way

16 Way

16 Way

32 Way

32 Way

 

520

520

570

570

595

595

 

7457

7457

7476

7476

7499

7499

 

16 GB

16 GB

256 GB

256 GB

384 GB MS

384 GB

 

23 DASD

23 DASD

924 DASD

924 DASD

1125 DASD

1125 DASD

Processor

00:35

4:54

01:53

6:39

02:41

6:06

MSD

 

 

 

 

 

 

SLIC MSD

04:50

15:40

24:10

42:18

43:10

40:03

IPL

 

 

 

 

 

 

with Copy

 

 

 

 

 

 

Shutdown

02:46

2:50

04:19

2:23

03:59

3:57

re-ipl

 

 

 

 

 

 

SLIC

01:59

2:17

03:59

5:22

04:16

6:21

re-ipl

 

 

 

 

 

 

OS/400

03:21

4:20

09:56

25:45

13:56

44:10

Total

13:31

30:01

44:17

1:22:27

1:08:02

1:40:37

The workloads were increased for iV5R4 to better reflect common system load affecting the MSD and the OS/400 portion of the

IPL

 

 

 

 

 

 