Intel 170 Servers, AS/400 RISC Server, 7xx Servers manual 14.2.3 12X Loop Testing

Models: 7xx Servers 170 Servers AS/400 RISC Server

1 368
Download 368 pages 6.76 Kb
Page 207
Image 207

14.2.3 12X Loop Testing

12X Loop testing from 1 571F to 8 571F IOAs with 36 DASD off each 571F

 

1800

 

 

 

 

 

 

 

 

1600

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

 

GB/HR

1200

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

800

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

Number of 571F IOAs

 

 

 

A 9406-MMA 8 Way system with 96 GB of mainstore and 396 DASD in #5786 EXP24 Disk Drawer on 3 12X loops for the system ASP were used, ASP 2 was created on a 4th 12X loop by adding 5796 system expansion units with 571F IOAs attaching 36 4327 70 GB DASD in #5786 EXP24 Disk Drawer with RAID5 turned on. I created a virtual tape drive in ASP2 and I used a 320GB file to save to the tape drive for this test.

When I completed the testing up to 288 DASD on 8 IOAs, I moved the 12X loop to the other 12X GX adapter in the CEC and ran the test again and saw no difference in the testing between the two loops. The 12X loop is rated for more throughput than the DASD configuration would allow for. So the test isn’t a tell all about the 12X loops capabilities only a statement of support to the maximum number of 571F IOAs allowed in the loop.

IBM i 6.1 Performance Capabilities Reference - January/April/October 2008

 

© Copyright IBM Corp. 2008

Chapter 14 DASD Performance

207

Page 207
Image 207
Intel 170 Servers, AS/400 RISC Server, 7xx Servers manual 14.2.3 12X Loop Testing