C H A P T E R 7 Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide

NMRL: Message: [CPUOpen connectionsCPS] drop below low water mark

Extended Data

CPU: Indicates that CPU Utilization triggered the alarm.

CON: Indicates that Total Active Connections triggered the alarm.

CPS: Indicates that Connections per Second triggered the alarm.

UTL Alarm CLI commands

To set Utilization Threshold Alarm time window:

set utl_window <seconds> (Range: 5-65000,

default: 15)

To set Utilization Threshold Alarm high-water value:

set utl_high <percentage> (Range: 2-100,

default: 90)

To set Utilization Threshold Alarm low-water value:

set utl_low <percentage> (Range: 1-99,

default: 60)

To display current settings:

show utl_window

show utl_high

show utl_low

Examples:

Intel 7115> set utl_window 10

Intel 7115> show utl_window

Utilization window set [secs]: 10.

Intel 7115> set utl_highwater 80

Intel 7115> show utl_highwater

Utilization High water mark [%]: 80

Intel 7115> set utl_lowwater 60

Intel 7115> show utl_lowwater

Utilization Low water mark [%]: 60

7-6

Page 134
Image 134
Intel A31032-001 manual UTL Alarm CLI commands, To set Utilization Threshold Alarm time window, To display current settings