C H A P T E R 2 Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide

Troubleshooting

Server and Network LEDs

If either the Network or Server LED fails to illuminate using either straight-through or crossover network cables, the problem may be elsewhere in the network. Verify by wiring around the 7110/7115.

Inline LED

The Fail-through switch allows you to control what happens in the event of a failure. It is located in a recess between the Network and Server connectors. Use a small screwdriver or paper clip to manipulate the switch. The two options are:

Allow traffic to flow through the 7110/7115 unprocessed. (Fail- through mode, indicated by a steadily illuminated Inline LED.)

Block traffic flow through the 7110/7115 entirely. (Fail-safe mode, indicated by a blinking Inline LED.)

Please see Appendix B for a table describing all permutations of LED operation.

Continuing Configuration

This concludes basic configuration of the 7110/7115. To configure the unit for production please continue with Chapter 3, Theory of Operations, or Chapter 4, Scenarios.

2-6

Page 22
Image 22
Intel A31032-001 manual Troubleshooting, Continuing Configuration, Server and Network LEDs