C H A P T E R 7

Alarm Types

To display Overload Alarm time window

show rsc_window

Examples:

Intel 7115> set rsc_window 10

Intel 7115> show rsc_window

Check refused SSL connections [secs]: 10

UTL: Utilization Threshold Alarm

This alarm monitors three utilization threshold values:

CPU

Connections per Second

Total Open Connections.

When enabled, an alarm is issued whenever any of the utilization values exceeds its high-water mark, or, having exceeded the high- water mark, drops below the low-water mark. The user defines the high and low-water marks. By default, the high-water mark is 90% and the low-water mark is 60%.

The data collected for utilization threshold metrics tends to be bursty, so a smoothing algorithm is used to prevent continuous alarms.The utilization window is a user-specified sliding interval during which data is collected and averaged. Consequently, shorter intervals are likely to result in some extraneous alarms. The interval can be set from 5 to 65000 seconds (default: 15).

Format:

A:yyyymmddhhmmss:UTL:ALRTNMRL:CPUCONCPS:/

*message*/

Where:

A:identifies the message as an alarm. yyyymmddhhmmss: is the timestamp.

UTL: identifies the message as an

Utilization Threshold Alarm.

Alarm Modifiers and Messages

ALRT: Message: [CPUOpen connectionsCPS] exceed high water mark

7-5