NB Reference Thermal Solution #1
Figure 6-1. First NB Reference Heatsink Measured Thermal Performance vs. Approach Velocity
| 1.50 | Ȍ |
|
|
|
|
|
| 1.40 |
|
|
|
|
|
|
(°C/W) | 1.30 |
|
|
|
|
|
|
1.20 |
|
|
|
|
|
| |
1.10 |
|
|
|
|
|
| |
Ȍca |
|
|
|
|
|
| |
1.00 |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
| 0.90 |
|
|
|
|
|
|
| 0.80 |
|
|
|
|
|
|
| 100 | 200 | 300 | 400 | 500 | 600 | 700 |
Flow Rate (LFM)
6.3Mechanical Design Envelope
While each design may have unique mechanical volume and height restrictions or implementation requirements, the height, width, and depth constraints typically placed on the E8500 chipset NB thermal solution are shown in Figure
When using heatsinks that extend beyond the NB reference heatsink envelope shown in Figure
24 | Intel® E8500 Chipset North Bridge (NB) and eXternal Memory |
| Bridge (XMB) Thermal/Mechanical Design Guide |