Intel NetStructure® MPCBL0001 High Performance Single Board Computer

Contents

Error Messages

9

9.1BIOS Error Messages

 

The following table lists the error messages.

Table 89.

BIOS Error Messages

 

 

 

 

 

Error Message

Explanation of Error Message

 

 

 

 

 

 

Timer Error

This timer is based on 8254 resides in ICH-3. Error message indicates an error while

 

 

 

programming the count register of the timer. This may indicate a problem with the timer in

 

 

 

ICH-3

 

 

 

 

 

 

CMOS Battery

BIOS will report this error message when status bit (RTC_REGD.Bit7) in ICH3 is low. This

 

 

Low

bit is hardwired to RTC power, so it will be low when the voltage in SuperCAP is low.

 

 

 

 

 

 

CMOS Settings

BIOS will load default value after it detects CMOS corruption. Error message is triggered if

 

 

Wrong

BIOS fails to load the default value to CMOS.

 

 

 

 

 

 

CMOS

CMOS contents failed the checksum check. Error message indicates that the CMOS data

 

 

Checksum Bad

has been changed by a program other than the BIOS or the CMOS is not retaining it's data

 

 

 

due to hardware malfunction

 

 

 

 

 

 

RAM R/W test

Error message indicates BIOS fail to read/write to memory content during RAM R/W test.

 

 

failed

RAM R/W test is executed during POST.

 

 

 

 

 

 

CMOS Date/

Error message indicates BIOS has detected an invalid value in date & time register. (e.g.:

 

 

Time Not Set

Invalid date = 50h or invalid month = 13h.

 

 

 

 

 

 

Clear CMOS

Error message indicates that Jumper J16-3 to 5 is set

 

 

Jumper

 

 

 

installed

 

 

 

 

 

 

 

Clear Password

Error message indicates that Jumper J16-1 to 3 is set

 

 

Jumper

 

 

 

installed

 

 

 

 

 

 

 

MFG Jumper

Error message indicates that Jumper J16-9 to 10 is set. (Jumper is used only in

 

 

installed

manufacturing test)

 

 

 

 

 

 

BMC is in

Error message indicates that Jumper J16-2 to 4 is set.

 

 

Update Mode

 

 

 

 

 

 

 

BMC does not

Error message appears when BIOS issue an IPMI command to IPMC, but IPMC is not

 

 

respond to

responsive to the command and does not return successful completion code to BIOS.

 

 

BIOS IPMI

 

 

 

command

 

 

 

 

 

 

 

System Event

Error message indicates the System Event Log storage is full.

 

 

Log is Full

 

 

 

 

 

 

 

Refresh timer

This timer is a counter based on 82C54 which provides memory refresh request signal

 

 

test failed

periodically. Memory content need to be refreshed to compensate for the gradual leakage

 

 

 

of charge from the capacitors which stores the data.

 

 

 

 

 

 

KBC BAT Test

Error message indicates that Keyboard controller BAT test has failed.

 

 

failed

 

 

 

 

 

 

Note: If user enabled "Wait for F1 Error" under BIOS setup screen and any of the above error message

 

was observed, the BIOS will wait for user input before proceeding with the boot up except:

 

1. CMOS Checksum BAD

138

 

Technical Product Specification

 

 

Order #273817

Page 138
Image 138
Intel MPCBL0001 manual Bios Error Messages, Explanation of Error Message