Intel NetStructure® MPCBL0001 High Performance Single Board Computer

Contents

3.4E-Keying

E-Keying has been defined in the PICMG 3.0 Specification to prevent board damage, prevent misoperation, and verify fabric compatibility. The FRU data contains the board point-to-point connectivity record as described in Section 3.7.2.3 of the PICMG 3.0 Specification.

Upon management power-on, the firmware sets the Fibre Channel ports to front panel by default. When the board enters M3 power state, the shelf manager reads in the board point-to-point connectivity record from FRU and determines whether the board can enable the Fibre Channel ports to the back plane. Set/Get Port State IPMI commands defined by the PICMG 3.0 Specification are used for either granting or rejecting the E-keys.

If user Fibre Channel selection is to the front, the firmware maintains the Fibre Channel ports to the front panel regardless of the shelf manager’s granting or rejecting of E-keys for the board.

Table 12 on page 46, describes the:

Connections to base and fabric interfaces on the MPCBL0001 board for E-keying purposes.

Link descriptor list for the two Gigabit Ethernet channels connected to the base interface and the two Fibre Channels on the fabric interface.

Table 12.

Link Descriptors for E-Keying

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Link

Link

Link Type

Link Type

 

Link Designator

Link Desc

 

 

Descriptor

Grouping

Extension

 

 

 

 

 

Value

 

 

 

Port 0 -

 

Interface

Channel

 

 

 

ID

 

 

 

 

 

 

 

 

 

 

3 Flags

 

Number

 

 

 

 

[31:24]

[23:20]

[19:12]

{11:8}

 

{7:6}

[5:0}

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Ethernet

0

0000

00000001

0001

 

00

000001

0x00001101

 

 

Port 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Ethernet

0

0000

00000001

0001

 

00

000010

0x00001102

 

 

Port 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

FC Port 1

0

0010

00000010

1000

 

01

000001

0x00202C41

 

 

 

 

 

 

 

 

 

 

 

 

4

FC Port 2

0

0010

00000010

1000

 

01

000010

0x00202C42

 

 

 

 

 

 

 

 

 

 

 

NOTE: Fibre Channel E-keying is only applicable to MPCBL0001FXX products.

3.5IPMC Firmware Code

IPMC firmware code is organized into boot code and operational code, both of which are stored in a flash module. Upon an IPMC reset, the IPMC executes the boot code and performs the following:

1.Self test to verify the status of its hardware and memory.

2.Sets up the internal real-time operating system (RTOS).

3.Performs a checksum of the operational code.

Upon successful verification of the operational code checksum, the firmware will jump to the operational code.

46

Technical Product Specification

 

Order #273817

Page 46
Image 46
Intel MPCBL0001 manual Ipmc Firmware Code, Link Descriptors for E-Keying