Intel NetStructure® MPCBL0001 High Performance Single Board Computer

Contents

Table 45. Power Distribution Connector (Zone 1) P10 Pin Assignments

8

GA3

Geographic Addr Bit 3

 

 

 

9

GA4

Geographic Addr Bit 4

 

 

 

10

GA5

Geographic Addr Bit 5

 

 

 

11

GA6

Geographic Addr Bit 6

 

 

 

12

GA7/P

Geo Adr Bit 7 (Odd Parity)

 

 

 

13

IPMB_CLK_A

IPMB Bus A Clock

 

 

 

14

IPMB_DAT_A

IPMB Bus A Data

 

 

 

15

IPMB_CLK_B

IPMB Bus B Clock

 

 

 

16

IPMB_DAT_B

IPMB Bus B Data

 

 

 

17

Unused

No Connect

 

 

 

25

EMI_GND

EMI Chassis Ground

 

 

 

26

LOGIC_GND

Gnd Ref for Card Logic

 

 

 

27

ENABLE_B

Enb DC-DC conv, B Feed

 

 

 

28

VRTN_A

-48 V Return, Feed A

 

 

 

29

VRTN_B

-48 V Return, Feed B

 

 

 

 

30

- 48 V_EARLY_A

-48

V In, Feed A Precharge

 

 

 

 

31

-48 V_EARLY_B

-48

V In, Feed B Precharge

 

 

 

32

ENABLE_A

Enb DC-DC conv, A Feed

 

 

 

 

33

-48V_A

-48

V Input, Feed A

 

 

 

 

34

-48V_B

-48

V Input, Feed B

 

 

 

 

4.1.2Data Transport Connector (Zone 2)

Zone 2 consists of one 120-pin HM-Zd connector, labeled P23, with 40 differential pairs. This data transport connector provides the following signals:

Two 10/100/1000Base-T/TX Ethernet base fabric channels (four differential signal pairs each, 16 signals total).

Two 2 Gbit Fibre Channel ports on the extended fabric (two differential signal pairs each, eight signals total).

The connector used is AMP/Tyco part number 1469001-1, Intel part number A66621-001. Figure 17, “Data Transport Connector (Zone 2) J23” on page 85 shows a face view of the connector.

Figure 17. Data Transport Connector (Zone 2) J23

HG FG DG BG

HG FE DC BA

1

2

3

4

5

6

7

8

9

10

B0899-01

The following naming convention describes the signals on this connector. Signal direction is defined from the perspective of MPCBL0001.

Technical Product Specification

85

Order #273817

 

Page 85