Image 13

Port Base Settings

NOTE: If you’re satisfied with the default port base setting as 5900, you can skip this section.

The default port base for switch connection is set at 5900. This means it will use port 5900 (port base) for viewer connection and port 5908 (port base + 8) for https Web browser connection.

for viewer connection: <Port base>

for secure browser connection: <Port base + 8>

However, if you intend to use your own port base setting, just access the Web Management interface and configure the port base as follows:

1. C

For example, if you choose 5970 as your port base, then you have:

for viewer connection: 5970

for secure browser connection: 5978

Template – Windows Internet Explorer

https://192.168.1.200.5978

Click “Submit” and “Apply Settings” to validate the new settings. The switch is now installed within your LAN, and you’re able to proceed with establishing a remote viewer connection.