GraphicsPrintingAppendix C
69PK80Series 80-Column Prin ter User’s Manual
ESC7 — CancelPrinting of Codes 128–159
This command is allowed for compatibility with the 6820 Printer but
causes no action on the PK80 Printer. Unlike the 6820 Printer, the default
for the PK80 Printer is ESC 6,notESC 7.
Hexadecimal Format
1b 37
Note: This commandis only availablewhen the default SBCS character
set is selected.
ESC I — Printable Code Area Expansion
This command sequence allows certain ASCII codes 0 to 1Fh tobe print-
able when the variable nis set to 1. This allows the use of these codes for
user-defined characters.If n= 0, the command returns 0 to1Fh to non-
printable control codes. Only the following codes can be redefined as
printable characters. Codes not listed print as s tandard control codes.
Hexadecimal Format
1b 49 n
PrintableCode Expansion Characters
Hex ASCII Hex ASCII
0NUL 11 DC1
1SOH 15 NAK
2STX 16 SYN
3ETX 17 ETB
4EOT 1c FS
5ENQ 1d GS
6ACK 1e RS
10 DLE 1f US
Note: This commandis only availablewhen the default SBCS character
set is selected.