Juniper Networks 8 manual ERX Modules, ERX-310 Router, Rear View AC Model

Models: 8

1 183
Download 183 pages 46.84 Kb
Page 27
Image 27

Figure 6: ERX-310 Router, Rear View (AC Model)

g013732

Figure 7: ERX-310 Router, Rear View (DC Model)

g013733

ERX Modules

ERX Overview

I/O module

SRP I/O module

ESD grounding jack

AC power inputs and switches A and B

Grounding posts

I/O module

SRP I/O module

ESD grounding jack

DC power inputs and switches A and B

Grounding posts

Each system supports an SRP module and a selection of line modules. You can use any line module for access or uplink . Access line modules receive traffic from low-speed circuits, and the system routes the traffic onto higher-speed uplink line modules and then to the core of the network.

Each module connects to a corresponding I/O module via a passive midplane. See Figure 8.

The front panel of each module contains a collection of status LEDs (light-emitting diodes). For information about how to interpret the LEDs, see “Troubleshooting” on page 103.

ERX Modules 9