ERX 8.0.x Hardware Guide

Table 13: Troubleshooting Abnormal LED Activity on Modules (continued)

Diagnostic Signs

Possible Problems

Actions

LINK LED is not lit

 

 

Ethernet connection is down.

1.

Make sure that Ethernet cables are

 

 

 

 

 

 

 

properly connected to both the

 

 

 

 

 

Ethernet port and the appropriate

 

 

 

 

 

network device.

 

 

 

 

2.

Contact Juniper Networks Customer

 

 

 

 

 

Service.

 

 

 

 

 

 

RED ALM is lit

 

 

System does not recognize a

1.

Make sure that all cables are firmly

 

 

 

 

 

port connection.

 

plugged into the ports and the

 

 

 

Cabling is not connected

 

attached network device.

 

 

 

2.

Verify that cables are clean.

 

 

 

 

 

 

properly.

 

 

 

Cable is faulty.

3.

Test for faulty cables.

 

 

 

 

 

 

Clocking problem exists.

4.

Verify clock source and

 

 

 

 

 

 

 

 

configuration.

 

 

 

 

5.

Reset system.

 

 

 

 

 

NOTE: Problem is corrected when

 

 

 

 

 

normal LED activity occurs.

 

 

 

 

 

 

YEL ALM is lit

 

 

Far end receive failure (FERF)

1.

Correct FERF problem.

 

 

NOTE: This LED is not functional on the

 

 

exists.

2.

Reset system.

 

 

 

HSSI line module.

NOTE: Problem is corrected when normal LED activity occurs.

System does not boot.

 

A slot group is overloaded.

 

Modules held offline.

 

 

FAIL LED lights.

 

 

1.Issue the show version command to display module status.

2.Review section on proper slot group configuration in “Installing Modules” on page 35.

3.Reconfigure system with correct slot group configuration.

4.Reset system.

No LED indications or obvious signs.

System temperature is too high. Vents are blocked.

Fans are not operating.

1.Look at your console for a message indicating the problem. If you have the system log set to a severity of WARNING or higher, a Warning message indicates the failure.

2.Issue the show environment command to display the temperatures. If the temperature is too high, power down the system.

3.Regulate temperature.

4.Reset system.

112

 

Understanding Status LEDs to Troubleshoot

 

Page 130
Image 130
Juniper Networks 8 manual 112