ERX 8.0.x Hardware Guide

might fail if the module has not completed initialization. Use the show version command to display line module status. Do not enter commands for a line module until its state is listed as online.

Troubleshooting Power Failures

The system’s distributed power system is designed to consume low levels of power and dissipate low levels of heat. See “System Specifications” on page 119 for specifications of power consumption and heat dissipation. If you suspect a power problem, see Table 10.

Table 10: Causes of Power Failures

Symptom

Possible Problems

Actions

System does not power up.

 

 

System is not receiving power.

The following actions apply to all of the

 

 

 

 

 

 

 

Module’s power supply has

possible problems:

 

 

 

1. Verify that all power connections

 

 

 

 

 

 

malfunctioned.

 

 

 

Power source cannot handle

 

are correct.

 

 

 

2. Verify that the power supply is

 

 

 

 

 

 

system load.

 

 

 

 

 

delivering the correct voltage,

 

 

 

 

 

current, and wattage to the system.

 

 

 

 

 

See “System Specifications” on

 

 

 

 

 

page 119.

 

 

 

 

3.

If the system still does not

 

 

 

 

 

operate, contact Juniper Networks

 

 

 

 

 

Customer Service.

 

 

 

 

 

System shuts down.

 

 

Temperature is too high.

The following actions apply to all of the

 

 

 

 

 

Power is lost.

possible problems:

 

 

 

1.

Verify that power connections are

 

 

 

 

 

 

 

 

 

 

 

 

properly attached.

 

 

 

 

2.

Verify that system is receiving

 

 

 

 

 

power.

 

 

 

 

3.

Look to see whether or not the

 

 

 

 

 

LEDs are lit.

 

 

 

 

4.

Run diagnostics on SRP and line

 

 

 

 

 

modules.

 

 

 

 

5.

If system does not not reset,

 

 

 

 

 

contact Juniper Networks

 

 

 

 

 

Customer Service.

 

 

 

 

 

 

Understanding Status LEDs to Troubleshoot

Module LEDs can show you the current status of a module and alert you to a problem with the module or one of its ports. We recommend you

104

 

Understanding Status LEDs to Troubleshoot

 

Page 122
Image 122