Maintaining ERX Routers

CAUTION: For port redundancy to operate correctly, both the primary and redundant ports on a GE I/O module must use the same type of SFP.

Installing SFPs

To install SFPs:

1.Put the antistatic wrist strap on your wrist, and connect the strap to the ESD grounding jack on your system.

2.Identify the following items on the SFP, as shown in Figure 41:

The connection circuitry on the base

The cable connectors on the front

The cable connectors are protected by a dust cover.

Figure 41: Example of SFP

Connection circuitry on base

Cable connectors on front g013436

CAUTION: Be sure to position the SFP correctly before you install it.

3.Hold the SFP so that:

The connection circuitry is adjacent to the TX and RX markings on the module’s faceplate.

The front will be visible when you install the SFP.

For the correct orientation, see Figure 42.