ERX 8.0.x Hardware Guide

Removing a Line Module, SRP Module, or SRP I/O Module

NOTE: We recommend that you issue the slot disable command from the CLI before removing a line module or I/O module.

CAUTION: If you do not use the halt command before removing or powering down an SRP, the system’s NVS card can become corrupted.

To remove a line module, SRP module, or SRP I/O module:

1.For SRP modules and SRP I/O modules, issue the appropriate halt command (halt, halt primary-srp, or halt standby-srp).

See JUNOSe System Basics Configuration Guide, Chapter 6, Managing Modules for information about the halt commands.

2.Ground yourself by using an antistatic wrist strap or other device and connect it to the ESD grounding jack on the chassis.

3.Use a screwdriver to loosen the thumb screws located at the top and bottom of the module panel.

4.Pull the ejector handles located at the top and bottom of the module so that they are in position 2, as shown in Figure 21.