OTHERS

– Warning display –

 

 

 

 

When an error occurs, BR-DV6000 automatically self-diagnoses the cause and displays an error- coded warning message on the monitor.

If BR-DV6000 is not in good order, or if an operation error has occurred, an alarm display will be shown on the monitor or the LCD.

Warning display

 

 

 

 

 

 

3 2 K C H Ð 1 / 2

 

 

S P 0 0 0 m i n

 

 

 

 

 

 

W A R N I N G

7 0 0 1

 

 

D R U M MO T O R

F A I L U R E

 

0 3 / 0 4 / 0 3

 

 

S T A N D B Y - O F F

1 1 : 2 0 : 0 0

T C R

0 2 : 0 0 : 0 0 : 0 0

 

 

 

 

 

 

Alarm display

 

 

 

 

3 2 K C H Ð 1 / 2

S P 0 0 0 m i n

 

 

 

 

H E A D C L E A N I N G R E Q U I R E D !

0 3 / 0 4 / 0 3

S T A N D B Y - O F F

1 1 : 2 0 : 0 0

T C R 0 2 : 0 0 : 0 0 : 0 0

Alarm display (Displayed regardless of the DISPLAY mode)

Display

Status

Action

LOW VOLTAGE

The DC power voltage is low.

Check the power voltage.

 

BR-DV6000 will eventually go into the OPER-

 

 

ATE OFF mode if operation is continued.

 

 

 

 

HEAD

The video head is dirty. (This message is dis-

Clean it with a JVC head-clean-

CLEANING

played when the DISPLAY mode is ON or

ing tape. (Page 8)

REQUIRED!

AUTO.) If the head is clogged, it will be detected

If the message persists despite

 

and the alarm message will be displayed in the

cleaning, it could be due to bad

 

PLAYBACK mode.The display disappears when

recording condition, defective

 

the cassette is ejected or the head gets cleared

tape or head lifespan.

 

of clog.

 

 

The message will also disappear when the head

 

 

cleaning tape is loaded.

 

 

 

 

OVER

The internal temperature of BR-DV6000 has ex-

Disconnect the power and place

HEATING!

ceeded the stated value.

BR-DV6000 in a cool place. If

 

 

this message is displayed

 

 

again, the unit may have been

 

 

damaged. In such a case, con-

 

 

sult your JVC authorized

 

 

dealer.

 

 

 

UNPLUG MAIN

This is a system error that occurs when the power

Unplug the power cord from the

POWER, PLUG

is turned on. The OPERATE indicator on BR-

power outlet and wait for some

BACK IN

DV6000 blinks in green. The unit will not accept

time before plugging it back in.

AFTER A

any operation commands.

 

WHILE

 

 

 

 

 

¥ For alarm displays resulting from operation errors, Refer to page 24.

97

Page 97
Image 97
JVC BR-DV6000U instruction manual Others,  Alarm display Displayed regardless of the Display mode