OTHERS | – Warning display – | ||
|
|
|
|
When an error occurs,
If
Warning display
|
|
|
|
|
|
3 2 K C H Ð 1 / 2 |
|
| S P 0 0 0 m i n | ||
|
|
|
|
| |
| W A R N I N G | 7 0 0 1 |
| ||
| D R U M MO T O R | F A I L U R E |
| ||
0 3 / 0 4 / 0 3 |
|
| S T A N D B Y - O F F | ||
1 1 : 2 0 : 0 0 | T C R | 0 2 : 0 0 : 0 0 : 0 0 | |||
|
|
|
|
|
|
Alarm display
|
|
|
|
3 2 K C H Ð 1 / 2 | S P 0 0 0 m i n | ||
|
|
|
|
H E A D C L E A N I N G R E Q U I R E D !
0 3 / 0 4 / 0 3 | S T A N D B Y - O F F |
1 1 : 2 0 : 0 0 | T C R 0 2 : 0 0 : 0 0 : 0 0 |
Alarm display (Displayed regardless of the DISPLAY mode)
Display | Status | Action |
LOW VOLTAGE | The DC power voltage is low. | Check the power voltage. |
|
| |
| ATE OFF mode if operation is continued. |
|
|
|
|
HEAD | The video head is dirty. (This message is dis- | Clean it with a JVC |
CLEANING | played when the DISPLAY mode is ON or | ing tape. (☞ Page 8) |
REQUIRED! | AUTO.) If the head is clogged, it will be detected | If the message persists despite |
| and the alarm message will be displayed in the | cleaning, it could be due to bad |
| PLAYBACK mode.The display disappears when | recording condition, defective |
| the cassette is ejected or the head gets cleared | tape or head lifespan. |
| of clog. |
|
| The message will also disappear when the head |
|
| cleaning tape is loaded. |
|
|
|
|
OVER | The internal temperature of | Disconnect the power and place |
HEATING! | ceeded the stated value. | |
|
| this message is displayed |
|
| again, the unit may have been |
|
| damaged. In such a case, con- |
|
| sult your JVC authorized |
|
| dealer. |
|
|
|
UNPLUG MAIN | This is a system error that occurs when the power | Unplug the power cord from the |
POWER, PLUG | is turned on. The OPERATE indicator on BR- | power outlet and wait for some |
BACK IN | DV6000 blinks in green. The unit will not accept | time before plugging it back in. |
AFTER A | any operation commands. |
|
WHILE |
|
|
|
|
|
¥ For alarm displays resulting from operation errors, Refer to page 24.