Inputting scan settings manually

Settings for the final scan can be made in the index scan or prescan windows.

Job-name list box

Load Job button

Save Job button

Input-resolution list box

Output-resolution list box

Input-size text boxes

Input-size lock button

Magnification text box

Output-size text boxes

Output-size lock button

Unit list box

Reset button

Image-size display

Input-resolution list box: values can be selected among the drop-down list or be entered into the box directly. The input-resolution range is from 200 dpi to the maximum resolution of 3200 dpi.

Output-resolution list box: values can be selected among the drop-down list or be entered into the box directly. Output-resolution cannot be entered if pixel is selected in the unit list box.

Input-size text box: input size is determined by either the cropping frame dimensions or the values entered in the width and height boxes. The cropping frame will adjust to any value entered. Input-size cannot be entered if pixel is selected in the unit list box.

Input-size lock button: to lock the input values. The cropping frame can be moved, but not resized while this button is clicked. Clicking the button again releases the lock. The input-size lock button cannot be used if pixel is selected in the unit list box.

Magnification text box: to set image magnification. This value is based on input and output resolution, or output and input size. The magnification text box cannot be used if pixel is selected in the unit list box.

54 ADVANCED SCANNING

Page 54
Image 54