Communication Confirmation:

Send: CR

Reply: CR>

Set and Get command:

Set Command: YControl_TypeFunctionParamCR

Reply: ZControl_TypeFunctionParamCR>

Get Command: YControl_TypeFunctionCR

Reply: ZControl_TypeFunctionParamCR>

Example 1 (select VGA1 as video input channel):

"Y01570CR" "Z01570CR>"

Example 2 (get selected current input channel):

"Y1157CR"

"Z11570CR>" (0 = VGA 1) Definition:

: ASCII Code 0x20

CR: ASCII Code 0x0D

After a set type Command setting, system responds with a string “Done”. The default data rate is 9600 Baud, with no parity, 8 data bits and 1 stop bit.