7: Setup Mode: Channel Configuration

Manual Connection

Attempts to connect when directed by a command string received from the serial port. The first character of the command string must be a C (ASCII 0x43), and the last character must be either a carriage return (ASCII 0x0D) or a line feed (0x0A). No blanks or space characters may be in the command string. Between the first and last command string characters must be a full or partial destination IP address and may be a destination port number.

The IP address must be in standard decimal-dot notation and may be a partial address, representing the least significant 1, 2, or 3 bytes of the remote IP address. The period is required between each pair of IP address numbers.

If present, the port number must follow the IP address, must be presented as a decimal number in the range 1-65535, and must be preceded by a forward slash (ASCII 0x2F). The slash separates the IP address and the port number. If you omit the port number from a command string, the internally stored remote port number starts a connection.

If a partial IP address is presented in a command string, it is interpreted to be the least significant bytes of the IP address and uses the internally stored remote IP address to provide the most significant bytes of the IP address. If the IP address entered is 0.0.0.0/0, the device server enters Monitor Mode.

For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23.

If an IP address does not follow the first command string character (which is "C"), the subsequent character string is interpreted as the host name and domain to be used in DNS lookup. This character string can include a destination port number as well. The port number can be preceded by either a forward slash (/) or a colon ( : ).

Table 7-6. Manual Connection Address Example

Command String

Result if remote IP is 129.1.2.3 and remote port is

 

 

 

1234

 

C121.2.4.5/1

 

Complete override; connection is started with host 121.2.4.5,

 

 

port 1

 

 

 

 

C5

 

Connects to 129.1.2.5, port 1234

 

 

 

 

 

C28.10/12

 

Connects to 129.1.28.10, port 12

 

 

 

 

 

C0.0.0.0/0

 

Enters Monitor Mode

 

 

 

 

 

Cwww.lantronix.com/80

 

Tries to connect to the Lantronix web server if the

 

 

 

<hostname:domain> (www.lantronix.com) is configured in the

 

 

 

DNS server database.

 

Autostart (Automatic

 

If you enable Autostart, the unit automatically connects to the

 

Connection)

 

remote IP address and remote port specified when the firmware

 

 

 

starts.

 

Hostlist

 

If you enable this option, the device server scrolls through the

 

 

 

hostlist until it connects to a device listed in the hostlist table.

 