12. Troubleshooting

This chapter discusses how you can diagnose and fix errors quickly without having to contact a dealer or Lantronix. It helps to connect a terminal to the serial port while diagnosing an error to view summary messages that may display. When troubleshooting, always ensure that the physical connections (power cable, network cable, and serial cable) are secure.

Note: Some unexplained errors might be caused by duplicate IP addresses on the network. Make sure that your unit's IP address is unique.

When troubleshooting the following problems, make sure that the xPico is powered up. Confirm that you are using a good network connection.

Problems and Error Messages

 

 

 

Problem/Message

Reason

Solution

 

 

 

When you issue the ARP –S

Your currently logged-in

Have someone from your IT

command in Windows, the

user does not have the

department log you in with

"ARP entry addition failed: 5"

correct rights to use this

sufficient rights.

message displays.

command on this PC.

 

 

 

 

When you attempt to assign an

When you Telnet to port

Telnet back to Port 1. Wait for it

IP address to the unit by the

1 on the device server,

to fail, then Telnet to port 9999

ARP method, the "Press Enter

you are only assigning a

again. Make sure you press

to go into Setup Mode" error

temporary IP address.

Enter quickly.

"(described below) message

When you Telnet into

 

displays. Now when you Telnet

port 9999 and do not

 

to the device server, the

press Enter quickly, the

 

connection fails.

device server reboots,

 

 

causing it to lose the IP

 

 

address.

 

When you Telnet to port 9999,

You did not press Enter

Telnet to port 9999 again, but

the "Press Enter to go into

quickly enough. You only

press Enter as soon as you

Setup Mode" message

have 5 seconds to press

see the "Press Enter to go into

displays. However, nothing

Enter before the

Setup Mode" message.

happens when you press

connection is closed.

 

Enter, or your connection is

 

 

closed.

 

 

xPico User Guide

73

Page 73
Image 73