2: Installation

Once the unit is running normally, the Power LED should be solidly lit to indicate the unit is ON, the Link LED should be solidly lit to indicate a functioning Ethernet connection, and the OK LED should blink green once every two seconds.

5.Supply power to the serial device.

6.Verify that the MSS is working. There are a few ways to check:

a)Wait for approximately 30 seconds after powering the unit up. If the Power and Link LEDs are solidly lit and the OK LED blinks green once every two seconds, the MSS is operating normally.

b)If you have connected a serial terminal to the MSS DB25 port, press the Return key. You should see several lines of start-up messages followed by a Local> prompt.

c)If an IP address is configured for the MSS, ping the MSS from a TCP/IP host. For more instructions, see the IP Address Configuration section in Getting Started.

Figure 2-14: Pinging the MSS

% ping XXX.XXX.XXX.XXX

MSS100 Specifications

Power (power cube adaptor)

Adapter:

Input:

110 VAC US; 100-240 VAC International

Output:

5 VDC

 

Current:

.74 amps

 

MSS100 power input requirement:

5 VDC regulated

Temperature

Note: Rapid temperature changes may affect operation. Do not operate near heating or cooling devices or areas that open to the outdoors.

Operating range:

5° to 50° C (41° to 122° F)

Storage range:

40° to 66° C (-40° to 151° F)

Max. temp change:

20° C (36° F) per hour

Humidity

 

Operating range:

10% to 90% non-condensing

 

40% to 60% recommended

Storage range:

10% to 90% non-condensing

Altitude

Note: For operations above 2.4 km (8,000 ft), decrease the operating temperature rating by 1.8°C for each 1,000 m (1°F for each 1,000 ft).

Operating

2.4 km (8,000 ft)

Storage

9.1 km (30,000 ft)