10: Monitor Mode

 

 

 

Table 10-1. Monitor Mode Commands

 

 

Command

Command Name

Function

 

 

VS x.x.x.x

Version

Queries software header record (16 bytes) of unit

 

 

 

 

with IP address x.x.x.x.

 

 

 

 

 

 

 

GC x.x.x.x

Get Configuration

Gets configuration of unit with IP address x.x.x.x as

 

 

 

 

hex records (120 bytes).

 

 

 

 

 

 

 

SC x.x.x.x

Send Configuration

Sets configuration of unit with IP address x.x.x.x

 

 

 

 

from hex records.

 

 

 

 

 

 

 

PI x.x.x.x

Ping

Pings unit with IP address x.x.x.x to check device

 

 

 

 

status.

 

 

 

 

 

 

 

AT

ARP Table

Shows the unit’s ARP table entries.

 

 

 

 

 

 

 

TT

TCP Connection

Shows all incoming and outgoing TCP connections.

 

 

 

Table

 

 

 

 

 

 

 

 

NC

Network Connection

Shows the unit’s IP configuration.

 

 

 

 

 

 

 

RS

Reset

Resets the unit’s power.

 

 

 

 

 

 

 

QU

Quit

Exits diagnostics mode.

 

 

 

 

 

 

 

G0, G1, ....,Ge, Gf

Get configuration

Gets a memory page of configuration information

 

 

 

from memory page

from the device.

 

 

 

 

 

 

 

S0, S1,...,Se, Sf

Set configuration to

Sets a memory page of configuration information

 

 

 

memory page

on the device.

 

 

 

 

 

 

 

GM

Get MAC address

Shows the unit's 6-byte MAC address.

 

 

 

 

 

 

 

SS

Set Security record

Sets the Security record without the encryption key

 

 

 

 

and length parameters. The entire record must still

 

 

 

 

be written, but the encryption-specific bytes do not

 

 

 

 

need to be provided (they can be null since they

 

 

 

 

are not overwritten).

 

 

 

 

 

 

Note: Entering any of the commands listed above generates one of the following command response codes:

Table 7-2. Command Response Codes

Response Meaning

0>

1>

2>

8>

9>

OK; no error

No answer from remote device

Cannot reach remote device or no answer

Wrong parameter(s)

Invalid command