| 4: Configuration Using |
|
Connect Mode: Active Connection | |||
|
|
| |
| Active Connect | Select None (default) to disable Active Connect. Otherwise, | |
|
| indicate the connection type from the | |
|
| With Any Character: Attempts to connect when any | |
|
| character is received from the serial port. | |
|
| With Active Mdm Ctrl In: Accepts external | |
|
| connection requests only when the | |
|
| modem_control_in input is asserted. | |
|
| With Start Character: Attempts to connect when it | |
|
| receives a specific start character from the serial | |
|
| port. The default start character is carriage return. | |
|
| Manual Connection: Attempts to connect when | |
|
| directed by a command string received from the | |
|
| serial port. | |
|
| Auto Start: Automatically connects to the remote IP | |
|
| address and port after booting up. | |
|
|
| |
| Start Character | If Active Connect is set to With Start Character, enter the | |
|
| start character in this field. The default setting is 0D. | |
|
|
| |
| Modem Mode | Indicates the | |
|
| (if Modem Mode is enabled). The default setting is None. | |
|
|
|
|
Endpoint Configuration |
|
| |
|
|
| |
| Local Port | Enter the local port number. | |
|
|
| |
| Auto increment for active | Select to | |
| connect | outgoing connections. The range of | |
|
| numbers is 50,000 to 59,999 and loops back to the beginning | |
|
| when the maximum range is reached. Disabled by default. | |
|
|
| |
| Remote Port | Enter the remote port number. | |
|
|
| |
| Remote Host | Enter the IP address of the remote device. | |
|
|
|
|
Common Options |
|
| |
|
|
| |
| Telnet Mode | This field is available for configuration only when Active | |
|
| Connect is set to None. Select Enable to permit Telnet | |
|
| communication to the UDS1100 unit. | |
|
|
| |
| Terminal Name | This field is available for configuration only when Telnet Mode | |
|
| is set to Enable. | |
|
| Use the terminal name for the Telnet terminal type. Enter only | |
|
| one name. When this option is enabled, the unit also reacts to | |
|
| the end of record (EOR) and binary options, which can be | |
|
| used for applications such as terminal emulation to IBM hosts. | |
|
|
| |
| Connect Response | A single character is transmitted to the serial port when there | |
|
| is a change in connection state. The default setting is None. | |
|
|
|
|
UDS1100 User Guide | 31 |