4: Configuration Using Web-Manager

Figure 4-3. Server Settings

To configure the UDS1100’s device server settings:

1.On the main menu, click Server.

2.Configure or modify the following fields:

Server Configuration

Telnet Password

Enter the password required for Telnet access.

 

 

Retype Password

Re-enter the password required for Telnet access.

 

 

Advanced

ARP Cache Timeout

When the unit communicates with another device on the

(secs)

network, it adds an entry into its ARP table. ARP Cache

 

timeout defines the number of seconds (1-600) before it

 

refreshes this table.

 

 

TCP Keepalive (secs)

TCP Keepalive time defines how many seconds the unit waits

 

during an inactive connection before checking its status. If the

 

unit does not receive a response, it drops that connection.

 

Enter a value between 0 and 60 seconds. 0 disables

 

keepalive. The default setting is 45.

 

 

Monitor Mode @ Bootup

Select Disable to disable entry into the monitor mode using

 

the yyy or xx1 key sequence at startup. This field prevents

 

the unit from entering monitor mode by interpreting the stream

 

of characters that are received during the device server's

 

initialization at startup. The default setting is Enable.

 

 

HTTP Server Port

This option allows the configuration of the web server port

 

number. The valid range is 1-65535. The default setting is 80.

 

 

UDS1100 User Guide

25

Page 25
Image 25
Lantronix manual To configure the UDS1100’s device server settings, Server Configuration, Advanced