7: Setup Mode: Channel Configuration

Figure 7-3. Manual Connection Address Example

 

 

 

 

Command String

 

 

Result if remote IP is 129.1.2.3 and remote port is 1234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C121.2.4.5/1

 

 

Complete override; connection is started with host 121.2.4.5,

 

 

 

 

 

 

 

 

port 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C5

 

 

Connects to 129.1.2.5, port 1234.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C28.10/12

 

 

Connects to 129.1.28.10, port 12.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C0.0.0.0/0

 

 

Enters Monitor Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Autostart (Automatic

 

 

 

If you enable Autostart, the unit automatically connects to the

 

 

 

 

Connection)

 

 

 

remote IP address and remote port specified when the firmware

 

 

 

 

 

 

 

 

 

 

starts.

 

 

 

 

 

 

 

 

 

 

 

 

 

Hostlist

 

 

 

If you enable this option, the device server scrolls through the

 

 

 

 

 

 

 

 

 

 

hostlist until it connects to a device listed in the hostlist table.

 

 

 

 

 

 

 

 

 

 

Once it connects, the unit stops trying to connect to any others. If

 

 

 

 

 

 

 

 

 

 

this connection fails, the unit continues to scroll through the table

 

 

 

 

 

 

 

 

 

 

until it is able to connect to another IP in the hostlist.

 

 

 

 

 

 

 

 

 

 

Hostlist supports a minimum of 1 and a maximum of 12 entries.

 

 

 

 

 

 

 

 

 

 

Each entry contains the IP address and the port number.

 

 

 

 

 

 

 

 

 

 

The hostlist is disabled for Manual and Modem Modes. The unit

 

 

 

 

 

 

 

 

 

 

does not accept a data connection from a remote device when

 

 

 

 

 

 

 

 

 

 

the hostlist option is enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4-7. Hostlist Option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UDS1100 User Guide