INSTALLATION

A-6

POWERARC® 5500 OUTPUT CONNECTIONS

Physical Location of Items and Components may vary by Code No.

Return to

Return to Section TOC

TOC

Return to

Return to Master TOC

TOC

FIGURE A.1 (For Codes 11182, 11187, 11215)

7

1

9

POWER ARC 5500

80

70AMPS

AMPS

125

90

AMPS

GENERATOR

AMPS

100

AMPS

POWERARC® 5500 OUTPUT CONNECTIONSPhysical Location of Items and Components may vary by Code No.Return toFIGURE A.1 (For Codes 11182, 11187, 11215)WARNING

6

ELECTRODE SELECTION GUIDE

2

FIGURE A.2 (For Codes 11403, 11404) 5

 

3

2

4

 

1.CURRENT CONTROL DIAL

2.WELD OUTPUT TERMINALS (2)

3.GROUND STUD

4.CIRCUIT BREAKERS (2) - 20 AMP

5.RECEPTACLE - 240 VOLT, 20 AMP

6.DUPLEX RECEPTACLE - 120 VOLT, 20 AMP

7.TACHOMETER / HOUR METER (CODE 11215 ONLY)

FIGURE A.2 (For Codes 11403, 11404)

1

POWER ARC 5500

80

70AMPS

AMPS

125

90

AMPS

GENERATOR

AMPS

100

AMPS

Return to SectionReturn to MasterELECTRICAL OUTPUTWELDING CABLE CONNECTIONSWARNING

8

ELECTRODE SELECTION GUIDE

7

 

4

5

3

6

 

 

1.CURRENT CONTROL DIAL

2.WELD OUTPUT TERMINALS (2)

3.GROUND STUD

4.CIRCUIT BREAKER- 20 AMP

5.RECEPTACLE - 240 VOLT, 20 AMP

6.DUPLEX RECEPTACLE - 120 VOLT, 20 AMP

7.TACHOMETER / HOUR METER (CODE 11404 ONLY)

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

ELECTRICAL OUTPUT

CONNECTIONS

See Figure A.1 for the location of the current control dial, weld output terminals, ground stud, circuit break- ers, 240 and 120 volt receptacles.

WELDING CABLE CONNECTIONS

Cable Size and Length

Be sure to use welding cables that are large enough. The correct size and length becomes especially important when you are welding at a distance from the welder.

Table A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length refers to the distance from the welder to the work and back to the welder. Cable diameters are increased for long cable lengths to reduce voltage drops.

TABLE A.1

RECOMMENDED WELDING CABLE

SIZE AND LENGTH

TOTAL COMBINED LENGTH OF ELECTRODE AND

WORK CABLES

 

 

 

Cable Size for

 

125 amp/

Cable Length

30% Duty Cycle

0-50 feet (0-15 meters)

6 AWG

50-100 feet (15-39 meters)

4 AWG

100-150 feet (30-46 meters)

3 AWG

150-200 feet (46-61 meters)

2 AWG

200-250 feet (61-76 meters)

1 AWG

 

 

POWERARC® 5500