Lincoln Electric SVM197-A NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM 115 VAC SUPPLY, Scope Settings

Models: SVM197-A

1 98
Download 98 pages 22.51 Kb
Page 71
Image 71
F-23

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-23

TROUBLESHOOTING AND REPAIR

F-23

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)

HIGH IDLE – NO LOAD

1 Period = 16.2 ms @ 3700 rpm

CH1

0 volts

50 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine 115 VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

POWERARC® 5500

Page 71
Image 71
Lincoln Electric SVM197-A NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM 115 VAC SUPPLY, Troubleshooting And Repair, Scope Settings