F-41

TROUBLESHOOTING AND REPAIR

F-41

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

 

No Load RPM

Load RPM

Maximum Speed

3725

3650

Minimum Speed

3675

3400

 

 

 

WELDER/GENERATOR OUTPUT1

Output Control

Field Volts

Field Amps

Open Circuit

Load Volts

Load Amps

 

 

 

 

Volts

 

 

 

 

Maximum

43 - 49

4.8 - 5.8

60 - 63

12 - 25

120

- 125

 

Minimum

55 - 60

14 - 27

75

- 85

 

 

 

 

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

115 Volt Receptacle2

Output

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Control

Volts

 

 

Volts

 

 

Maximum

236 - 248

215 - 230

18 - 20

123 - 129

112 - 120

18 - 20

 

 

 

 

 

 

 

1Current Control Dial set at MAXIMUM or GENERATOR.

2Output values of each receptacle can vary within the range shown

POWERARC® 5500

Page 89