TROUBLESHOOTING AND REPAIR

F-31

CAPACITOR AND/OR DIODE BRIDGE

REMOVAL AND REPLACEMENT PROCEDURE

CAPACITOR AND/OR DIODE BRIDGEWARNING

Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

The following procedure will aid the technician in accessing and removing the capacitor and diode bridge for maintenance or replacement of either component.

MATERIALS NEEDED

5/16” Nut driver 5/16” Wrench

Jumper wire with alligator clips on each end for discharging the field capacitor Phillips head screw driver

Needle nose pliers Wiring Diagram