![EXTERNAL CONSOLE SPEAKER CONNECTION](/images/new-backgrounds/54798/5479821x1.webp)
EXTERNAL CONSOLE SPEAKER CONNECTION
✦ An external console speaker sounds system tones |
and alerts occupants with a loud siren during alarm. |
✦ With the |
can talk to the occupants through the external |
console speaker. |
EXTERNAL CONSOLE SPEAKER
✦ Use an |
not use a horn/siren with a |
✦ Up to two |
Console. |
✦ Up to 150 feet of 22 AWG wire can be used with |
each speaker. |
✦ The system tone volume can be adjusted with the |
annunciator volume control. |
| LINEAR SECURITY CONSOLE MODEL |
| ANNUNCIATOR |
| VOLUME |
MAIN | CONTROL |
| |
TERMINAL |
|
BLOCK | OPTIONAL |
| VOICE MODULE |
| MODEL: |
MAIN TERMINAL BLOCK
| AC | |
| AC | |
EXT. SPKR(S) | EXT. SPKR | |
8 OHM/10 WATT | ||
2 SPKRS MAX. | H/A - | |
NOTE: REMOVE | ||
H/A + | ||
JUMPER FOR | RELAY N.O. | |
EXT. SPEAKERS | RELAY DRY | |
|
1. | Mount the external speaker. |
2. | Route the speaker wires from the external speaker |
| to the Console. |
3. | Open the Console top cover and locate the main |
| terminal block. |
4. | Route the speaker wires up through the wiring |
| access hole. |
5. | Remove the wire jumper from the EXT. SPKR & |
| terminals. |
6. | Connect the speaker wires to the EXT. SPKR & |
EXTERNAL
CONSOLE
SPEAKER
8 OHM, 10 WATT
MINIMUM
REMOVE
terminals. |
✎NOTE: If connecting two external speakers, connect the second speaker in parallel, to the same EXT. SPKR &
EXTERNAL ALARM SIREN CONNECTION
✦ An external siren alerts occupants and neighbors |
with a loud siren during alarm. |
✦ Use a 12 volt, 1 amp maximum rated weather- |
resistant horn speaker with a |
JUMPER
CONNECT SPEAKER LEADS TO EXT. SPKR &
EXTERNAL
ALARM
SIREN
not use a plain speaker. |
✎NOTE: Connection of an electromechanical bell or motor bell is not recommended because of the radio interference generated when the bell is running.
✎UL NOTE: Not for use in UL installations.
1. | Mount the external siren. |
2. | Route the wires from the external siren to the |
| Console. |
3. | Open the Console top cover and locate the main |
| terminal strip. |
4. | Route the siren wires up through the wiring access |
| hole. |
| LINEAR SECURITY CONSOLE MODEL |
MAIN |
|
TERMINAL |
|
BLOCK | OPTIONAL |
| VOICE MODULE |
| MODEL: |
MAIN TERMINAL BLOCK
| AC | |
| AC | |
EXTERNAL SIREN | EXT. SPKR | |
12 VDC 1 AMP | ||
H/A - | ||
MAXIMUM | ||
| H/A + | |
| RELAY N.O. | |
| RELAY DRY |
5. Connect the siren wires to the RELAY N.O. & |
terminals. |
✎NOTE: By removing the Console’s auxiliary fuse, the relay contacts will become isolated. Use the RELAY N.O. & RELAY DRY terminals to switch an externally powered load.
EXTERNAL
ALARM RELAY 12 VDC 1 AMP MAXIMUM
CONNECT SIREN LEADS TO
9