4 BY 2 FORMAT POINT ID REPORTING CODES
4 BY 2 FORMAT POINT ID ALARM REPORT CODES
✦Refer to the 4 by 2 Format Point ID Reporting Code table to view/edit the alarm reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor triggers an alarm. The factory settings are listed, along with a blank area to write in the new installation values.
✦Use program Steps #210 - 233 to change the 4 by 2 Point ID alarm reporting codes.
✎NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of sensors.
2ABC
PROGRAMMING STEPS #210 TO #233
PROGRAM
0 - 99 FOR SENSOR ALARM CODE
(0 = NO REPORT)
STORE PROGRAM
STEPS #210-233
Any value from
4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES
✦Refer to the 4 by 2 Format Point ID Reporting Code table to view/edit the trouble reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor has a low battery or trouble condition. The factory settings are listed, along with a blank area to write in the new installation values.
✦Use program Steps #234 - 257 to change the 4 by 2 Point ID trouble reporting codes.
✎NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of sensors.
2ABC
PROGRAMMING STEPS #234 TO #257
PROGRAM
0 - 99 FOR SENSOR TROUBLE CODE (0 = NO REPORT)
STORE PROGRAM
STEPS #234-257
Any value from
40