Linear DVS-2400 4 BY 2 FORMAT POINT ID REPORTING CODES, 4 BY 2 FORMAT POINT ID ALARM REPORT CODES

Models: DVS-2400

1 44
Download 44 pages 42.75 Kb
Page 42
Image 42
4 BY 2 FORMAT POINT ID REPORTING CODES

4 BY 2 FORMAT POINT ID REPORTING CODES

4 BY 2 FORMAT POINT ID ALARM REPORT CODES

Refer to the 4 by 2 Format Point ID Reporting Code table to view/edit the alarm reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor triggers an alarm. The factory settings are listed, along with a blank area to write in the new installation values.

Use program Steps #210 - 233 to change the 4 by 2 Point ID alarm reporting codes.

NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of sensors.

2ABC

PROGRAMMING STEPS #210 TO #233

PROGRAM

0 - 99 FOR SENSOR ALARM CODE

(0 = NO REPORT)

STORE PROGRAM

STEPS #210-233

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).

4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES

Refer to the 4 by 2 Format Point ID Reporting Code table to view/edit the trouble reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor has a low battery or trouble condition. The factory settings are listed, along with a blank area to write in the new installation values.

Use program Steps #234 - 257 to change the 4 by 2 Point ID trouble reporting codes.

NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of sensors.

2ABC

PROGRAMMING STEPS #234 TO #257

PROGRAM

0 - 99 FOR SENSOR TROUBLE CODE (0 = NO REPORT)

STORE PROGRAM

STEPS #234-257

Any value from 0-99 can be programmed for each event using these steps (enter “0” to stop an event from reporting).

40

Page 42
Image 42
Linear DVS-2400 manual 4 BY 2 FORMAT POINT ID REPORTING CODES, 4 BY 2 FORMAT POINT ID ALARM REPORT CODES, STEPS #210-233