CALL LIMITER

CALL LIMITER

The factory setting for the call limiter is OFF. This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered.

STEP #101 The Console can be programmed to only allow fi ve burglary reports total per arming period using this step.

NOTE: Sensors programmed for 24-hour functions (Emergency, Panic, Fire) always send a Central Station report and always sound the local siren regardless of the Call Limiter setting.

1

0PROGRAMMING STEP #101

1

HOME PROGRAM

0 FOR OFF (UNLIMITED)

1 FOR ON (5 VIOLATIONS)

AWAY STORE PROGRAM

DIALING DELAY

The factory setting will cause the communicator to dial the Central Station instantly when an alarm or supervisory event occurs.

STEP #103 The communicator can be programmed to wait 30 seconds before dialing using this step. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.

1

0PROGRAMMING STEP #103

3DEF

HOME PROGRAM

0 FOR NO DELAY

1 FOR 15 SECOND DELAY

AWAY STORE PROGRAM

DIALING METHOD

The factory setting causes the communicator to dial using DTMF (dual-tone multi-frequency) tone dialing.

STEP #104 The communicator can be programmed to use pulse (rotary) dialing using this step. Use this option if the telephone line in the installation does not support tone dialing.

1

0PROGRAMMING STEP #104

4GHI

HOME PROGRAM

0 FOR TONE DIALING

1 FOR PULSE DAILING

AWAY STORE PROGRAM

34