EXAMPLE INSTALLATION (WITH DXS-31 SHOWN)

The DXS-31 and DXS-32 sensors can be used to monitor doors, windows, cabinets, crawl space doors, gates, freezer doors, and many other moving objects that could be used for intrusion or need to be monitored.

A built-in magnetic switch triggers the sensor when its magnet (mounted on the moving part or the door or window) moves away from the sensor.

The DXS-31 sensor can be wired to external normally closed switches for remote triggering.

The DXS-31 sensor can connect directly to a glass break detector.

SET SENSOR JUMPER

A jumper inside the door/window sensor selects instant or delayed response.

1A. If the sensor is going to be used on the primary entry/exit door make sure that the jumper is in the DELAY position.

1B. If the sensor is going to be used on a window or a door that is not going to be used to enter and exit the premises, set the jumper to the INSTANT position.

LEFT OPENING DOOR

TRANSMITTER

MOUNTED ON

DOOR JAMB

(NOTE: SMALL END OF TRANSMITTER UP)

MAGNET

MOUNTED

ON DOOR

RIGHT OPENING DOOR

TRANSMITTER

MOUNTED ON

DOOR JAMB

(NOTE: SMALL END

OF TRANSMITTER DOWN)

MAGNET MOUNTED

ON DOOR

INSTANT/DELAY

OPTION JUMPER

MAGNET

INPUTALIGNMENT

SELECTMARK

JUMPER

TRANSMIT

INDICATOR

TEST

SWITCH

SLIDING WINDOW

MAGNET MOUNTED

ON WINDOW FRAME

TRANSMITTER

MOUNTED ON

WINDOW SILL

DOUBLE-HUNG

WINDOW

4.Snap sensor onto mounting plate. TRANSMITTER

MOUNTED ON

WINDOW FRAME

MAGNET

MOUNTED

ON WINDOW

SASH STILE

ANTENNA

TWO TYPE 2032

BATTERIES

BATTERY

CLAMP

SCREW

BATTERY CLAMP

EXTERNAL

INPUT

TERMINALS

CHOOSE MOUNTING METHOD

2A. Apply double-stick tape (supplied) to back of sensors and magnets.

2B. Screws are also provided to mount sensors and magnets. Screws are preferred over the double-stick tape in permanent installations.

UL NOTE: Double-stick tape is not allowed in UL installations.

ATTACH SENSORS AND MAGNETS

Allow a maximum of 1/2" between magnet and sensor when door/window is closed.

The magnet height is adjustable and an optional magnet spacer is provided for uneven surfaces.

3B. On doors, mount sensor to door frame and magnet to door.

3B. On windows, mount sensor to window frame and magnet to window.

NOTE: Magnet must line up with mark on sensor case both horizontally & vertically.

4.Snap sensor onto mounting plate.

TEST SENSORS

INSTANT/DELAY

 

OPTION JUMPER

SELECTS

 

INSTANT

SELECTS

DELAY

ATTACH MOUNTING PLATES

USING THE SCREWS OR

DOUBLE-STICK TAPE PROVIDED

NOTE: ATTACHING THE TRANSMITTER WITH DOUBLE-STICK TAPE IS NOT ALLOWED IN UL INSTALLATIONS

In Chime Mode, the Console should “ding-dong” when the sensor sends a signal.

5.Open door or window.

Verify that light on the sensor (if there is one) glows momentarily when door/window is opened.

Status indicator on the Console should remain lit for each door/window sensor that is left open.

OPEN DOOR, TRANSMIT INDICATOR SHOULD LIGHT

1.PLACE RECEIVER INTO PROGRAM OR "LEARN" MODE

2.ACTIVATE TRANSMITTER BY OPENING DOOR OR WINDOW

3.VERIFY THAT THE RECEIVER ACCEPTED THE SIGNAL

4.REPLACE TRANSMITTER COVER WHEN FINISHED

NOTE: THE TRANSMIT INDICATOR WILL ONLY LIGHT DURING TRANSMISSIONS WHEN THE CASE IS OPEN (EXCEPT WHEN PUSHING THE CASE FOR TESTING)