Linear DVS-2400 manual Changing A Sensors Supervision, Changing A Sensors Restore Requirements

Models: DVS-2400

1 44
Download 44 pages 42.75 Kb
Page 28
Image 28
CHANGING A SENSORS SUPERVISION

CHANGING A SENSORS SUPERVISION

When a sensor is programmed, the Console automatically recognizes it as supervised or non-supervised.

The Console expects hourly status transmissions from any sensor programmed as supervised.

Any sensor can be programmed as supervised or non-supervised.

NOTE: Don't program a sensor that doesn't send status transmissions as supervised.

SENSOR NUMBER

TO CHANGE

HOME PROGRAM

16 FOR NON-SUPERVISED

17 FOR SUPERVISED

AWAY STORE PROGRAM

CHANGING A SENSORS RESTORE REQUIREMENTS

When a sensor is programmed, the Console automatically recognizes it as manual or automatic restoring.

The Console expects restoral signals from any wireless sensor programmed as manual restore.

Any sensor can be programmed as manual or automatic restore.

NOTE: Don't program a sensor that doesn't send restoral transmissions as manual restore.

SENSOR NUMBER

TO CHANGE

HOME PROGRAM

18 FOR MANUAL RESTORE

19 FOR AUTO RESTORE

AWAY STORE PROGRAM

ENTRY DELAY TIME

The factory-set Entry Delay time is 30 seconds.

STEP #25 The Entry Delay time can be adjusted from 20 to 255 seconds using this step.

Write the new Entry Delay time in the User's Guide.

NOTE: Don't make the Entry Delay too short. The user may not have enough time to disarm the system before an alarm.

PROGRAMMING STEP #25

CHANGING A SENSORS RESTORE REQUIREMENTS JKL

PROGRAM

TIME IN SECONDS (20-255)

STORE PROGRAM

EXIT DELAY TIME

The factory-set Exit Delay time is 60 seconds.

STEP #26 The Exit Delay time can be adjusted from 20 to 255 seconds using this step.

Write the new Exit Delay time in the User's Guide.

AWAY

PROGRAMMING STEP #26

PROGRAM

TIME IN SECONDS (20-255)

STORE PROGRAM

BURGLARY SIREN TIME

The factory-set burglary siren time is fi ve minutes (UL installation maximum).

STEP #30 The burglary siren time can be adjusted from one to 30 minutes using this step.

3DEF

PROGRAMMING STEP #30

0

HOME PROGRAM

TIME IN MINUTES (1-30)

AWAY STORE PROGRAM

EMERGENCY SIREN TIME

The factory-set emergency siren time is fi ve minutes (UL installation maximum).

STEP #31 The emergency siren time can be adjusted from one to 30 minutes using this step.

3DEF

PROGRAMMING STEP #31

1

HOME PROGRAM

TIME IN MINUTES (1-30)

AWAY STORE PROGRAM