AUTOMATION OUTPUT MODE DURING ALARM
✦The factory setting causes the Automation Output to fl ash if it is programmed to activate during or after an alarm.
✎NOTE: For the Automation Output to activate during or after an alarm, that function must be enabled with Programming Step 71 or 72.
STEP #68 The output can be programmed to be a steady output using this step.
6MNO
PROGRAMMING STEP #68
8TUV
HOME PROGRAM
0 FOR FLASHING OUTPUT ON ALARM
1 FOR STEADY OUTPUT ON ALARM
AWAY STORE PROGRAM
AUTOMATION ACTIVATION TONE
✦The factory setting causes the Console to sound a
“Bing” when the Automation Output is activated by pressing the key, or when it's triggered with a
STEP #69 This sound can be silenced using this step.
6MNO
PROGRAMMING STEP #69
9WXY
HOME PROGRAM
0 FOR BING TONE OFF
1 FOR BING TONE ON
AWAY STORE PROGRAM
REMOTE CONTROL ARM/DISARM CHIRP
✦When arming with the portable remote control, the factory setting causes the Console to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed.
STEP #70 These chirps can be silenced using this step.
✎NOTE: If these chirps are silenced, it is recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the Console.
7PRS
PROGRAMMING STEP #70
0
HOME PROGRAM
0 FOR CHIRPS OFF
1 FOR CHIRPS ON
AWAY STORE PROGRAM
AUTOMATION OUTPUT ON DURING AND AFTER ALARM
✦The factory setting causes the Console's
Automation Output to activate when pressing the key, or when it's triggered with a
STEP #71 The Console can be programmed to activate the Automation Output during and after any alarms as well as when normally triggered using this step.
7PRS
1
HOME
PROGRAMMING STEP #71
PROGRAM
0 FOR STANDARD TRIGGER
1 FOR FLASHING DURING & AFTER ALARM
✎NOTE: The output will continue until the flashing sensor status lights are cleared.
AWAY
STORE PROGRAM
AUTOMATION OUTPUT ON DURING ALARM
✦The factory setting causes the Console's
Automation Output to activate when pressing the key, or when it's triggered with a
STEP #72 The Console can be programmed to activate the Automation Output during alarms as well as when normally triggered using this step.
✎NOTE: The Automation Output can be programmed to flash or be steady during alarm, see Programming Step 68.
7PRS
PROGRAMMING STEP #72
2ABC
HOME PROGRAM
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING ALARM
AWAY STORE PROGRAM
29