Linear DVS-2400 manual Report Console Trouble, Report Force Arming, Opening And Closing Reports

Models: DVS-2400

1 44
Download 44 pages 42.75 Kb
Page 39
Image 39
REPORT CONSOLE TROUBLE

REPORT CONSOLE TROUBLE

The factory setting does not report Console trouble events to the Central Station.

STEP #108 The communicator can be programmed to report Console trouble events using this step. These include all conditions that light the Console’s BATTERIES or TROUBLE indicator. It also includes low Console backup battery.

PROGRAMMING STEP #108

PROGRAM

0 FOR NO CONSOLE TROUBLE

1 FOR CONSOLE TROUBLE

STORE PROGRAM

REPORT FORCE ARMING

The factory setting does not send force arming reports.

STEP #110 The communicator can be programmed to report force arming anytime the Console is armed with one or more bypassed sensors using this step.

The factory set reporting code for force arming is “65” (Code 574 with Ademco).

NOTE: If force arming is enabled, and the Console is force armed (armed with an open sensor) remotely by telephone, or with the RA-2400 Remote Access software, the caller will be disconnected if the communicator is enabled.

PROGRAMMING STEP #110

PROGRAM

0 FOR NO FORCE ARMING RPTS.

1 FOR FORCE ARMING RPTS.

STORE PROGRAM

OPENING AND CLOSING REPORTS

The factory setting does not send opening and closing reports.

STEP #111 The communicator can be programmed to send an opening report when the system is disarmed, and a closing report when the system is armed for all users, or just the master user using this step.

NOTE 1: For commercial installations with retail traffic using opening and closing reports, it is recommended to disable quick arming to prevent customers from arming the system.

NOTE 2: The reporting codes are fixed for opening and closing. A unique code is reserved for the master user code and each of the five restricted user codes.

NOTE 3: Arming or disarming with the page alert user code dials the supervisory number, no opening or closing report is sent.

PROGRAMMING STEP #111

PROGRAM

0 FOR NO OPEN/CLOSE REPORTS

1 FOR O/C RPTS. FOR ALL USERS

2 FOR O/C RPTS. FROM MASTER USER ONLY

STORE PROGRAM

POINT ID REPORTING

The factory setting enables Point ID and allows the communicator to send two-digit alarm and trouble codes for each sensor. The individual sensor that causes an alarm or trouble report can be identifi ed at the Central Station.

STEP #113 Point ID can be disabled using this step. The Central Station will only receive general alarm and trouble reports.

PROGRAMMING STEP #113

PROGRAM

0 FOR GENERAL REPORTS ONLY

1 FOR POINT ID REPORTING

STORE PROGRAM