Linear DVS-2400 manual System Reporting Codes, STEPS #261-266, Force Arming Reporting Code

Models: DVS-2400

1 44
Download 44 pages 42.75 Kb
Page 41
Image 41
SYSTEM REPORTING CODES

SYSTEM REPORTING CODES

Refer to the System Reporting Codes table to

view/edit the reporting codes for the keypad FIRE

2 ABC

 

 

PROGRAMMING STEPS

and EMERGENCY buttons and for each of the

6 MNO

#261 TO #266

 

four Console conditions. The factory settings are

 

 

listed, along with a blank area to write in the new

 

PROGRAM

installation values.

 

 

 

STEPS #261-266

 

0 - 99 FOR CONSOLE

 

REPORTING CODE

Any value from 0-99 can be programmed for each

 

STORE PROGRAM

event using these steps (enter “0” to stop an event

 

 

 

from reporting).

 

 

FORCE ARMING REPORTING CODE

 

 

The factory set reporting code for force arming is

2 ABC

 

 

 

“65” (Code 574 with Ademco).

5 JKL PROGRAMMING STEP #258

STEP #258 Any value from 0-99 can be programmed for this

8 TUV

 

 

 

event using this step (0 = no report).

 

PROGRAM

NOTE: For force arming reporting, force arming

 

0 - 99 FOR FORCE ARMING

reports must be enabled. See Page 37.

 

REPORTING CODE

 

 

STORE PROGRAM

DURESS REPORTING CODE

The factory set reporting code for Duress is “66” (Code 121 with Ademco).

STEP #259 Any value from 0-99 can be programmed for this event using this step (0 = no report).

NOTE: For duress code reporting a keypad duress code must be programmed. See Page 30.

2ABC

PROGRAMMING STEP #259

9WXY

PROGRAM

0 - 99 FOR DURESS CODE

STORE PROGRAM

SYSTEM REPORTING CODES

STEP #

PROGRAMMING FUNCTION

POSSIBLE

FACTORY

ADEMCO VALUE

INSTALLATION

4 BY 2 VALUES

4 BY 2 VALUES

4 BY 2 VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

258

FORCE ARMING REPORT CODE

0 - 99

 

65

 

574

 

 

 

 

 

 

 

 

 

 

259

DURESS REPORT CODE

0 - 99

 

66

 

121

 

 

 

 

 

 

 

 

 

 

261

SYSTEM FIRE REPORT CODE

0 - 99

 

68

 

110

 

 

 

 

 

 

 

 

 

 

262

SYSTEM EMERGENCY REPORT CODE

0 - 99

 

69

 

120

 

 

 

 

 

 

 

 

 

 

263

SYSTEM TEST/CANCEL REPORT CODE

0 - 99

 

70

 

406

 

 

 

 

 

 

 

 

 

 

264

SYSTEM LOW BATTERY RESTORAL REPORT CODE

0 - 99

 

71

 

R302

 

 

 

 

 

 

 

 

 

 

265

SYSTEM LOW BATTERY CODE

0 - 99

 

73

 

E302

 

 

 

 

 

 

 

 

 

 

 

 

 

System Reporting Codes Table

 

 

 

 

 

 

 

 

 

 

 

 

 

OPENING & CLOSING REPORTING CODES TABLE

 

 

 

USER CODE

 

4 x 2 CLOSING

 

4 x 2 OPENING

 

ADEMCO CLOSING

ADEMCO OPENING

 

 

(ARMING) CODE

 

(DISARMING) CODE

 

(ARMING) CODE

(DISARMING) CODE

 

 

 

 

 

MASTER USER CODE1

 

74

 

82

 

R401 C000

E401 C000

 

 

 

 

 

 

 

 

RESTRICTED USER CODE #1

 

75

 

83

 

R401 C001

E401 C001

 

 

 

 

 

 

 

 

RESTRICTED USER CODE #2

 

76

 

84

 

R401 C002

E401 C002

 

 

 

 

 

 

 

 

RESTRICTED USER CODE #3

 

77

 

85

 

R401 C003

E401 C003

 

 

 

 

 

 

 

 

RESTRICTED USER CODE #4

 

78

 

86

 

R401 C004

E401 C004

 

 

 

 

 

 

 

 

RESTRICTED USER CODE #5

 

79

 

87

 

R401 C005

E401 C005

 

 

 

 

 

 

 

PAGE ALERT USER CODE

 

 

 

(DIALS PAGE NUMBER ONLY, NO CODES REPORTED)

 

 

 

 

 

 

 

 

 

REMOTE ARM & QUICK ARM

 

81

 

 

 

R407 C007

 

 

 

 

 

 

 

 

 

REMOTE DISARM

 

 

 

89

 

 

E407 C007

 

 

 

 

 

 

 

 

 

Opening & Closing Reporting Codes Table

39

Page 41
Image 41
Linear DVS-2400 manual System Reporting Codes, STEPS #261-266, Force Arming Reporting Code, Duress Reporting Code