Ice and Water Service (continued)
Replacement Filter Cartridges
For replacement filter cartridges or for service, contact your local dealer or Maytag Appliances Sales Company, Maytag Customer Assistance,
Replacement Filter Model Number for Models with
Water Filter Change Reminder Only: UKF7002AXX - Taste, odor, chlorine, cysts and lead
Replacement Filter Model Number for Models without
Water Filter Change Reminder:
UKF7001AXX - Taste, odor, chlorine, cysts and lead UKF6001AXX - Taste, odor, chlorine and lead UKF5001AXX - Taste, odor and chlorine
The PuriClean™ water filter is manufactured for Maytag Appliances by:
Cuno Incorporated
400 Research Parkway
Meriden, CT 06450
Rated Flow: | .5 gpm (1.9 L) |
Min. Op. Temp: | 33° F (.6° C) |
Max. Op. Temp: | 100° F (38° C) |
Min. Op. Press: | 30 psi (207 KPa) |
Max. Op. Press: | 125psi (862 KPa) |
The filters listed below have been tested and certified to NSF International under ANSI/NSF Standards 42 and 53 for the reduction of impurities as indicated:
NSF® |
| Models Without Water | Models With Water Filter | |||
Filter Change Reminder | Change Reminder | |||||
| ||||||
| UKF7001AXX |
| UKF6001AXX | UKF5001AXX | UKF7002AXX | |
Taste/Odor | Yes |
| Yes | Yes | Yes | |
Chlorine Class 1 Std.42 | Yes |
| Yes | Yes | Yes | |
|
|
|
|
|
| |
Turbidity Std.53 | Yes |
| No | No | Yes | |
|
|
|
|
|
| |
Particulate Std. 42 | Yes (Class I) |
| Yes (Class I) | No | Yes (Class I) | |
Cyst Std. 53 | Yes |
| No | No | Yes | |
Lead Std. 53 | Yes |
| Yes | No | Yes | |
|
|
|
|
|
| |
Capacity | 250 gal. (946 L) |
| 250 gal. (946 L) | 500 gal. (1893 L) | 416 gal. (1574 L) | |
|
|
|
|
|
| |
Function | Chemical/ |
| Chemical/ | Chemical | Chemical/Mechanical | |
| Mechanical |
| Mechanical |
|
|
See accompanying Product Data Sheets for further information on filters.
Care and CleaningCAUTION: Disconnect the power cord before cleaning. Do not touch refrigerated surfaces with wet or damp hands. Damp objects stick to cold metal surfaces. Before cleaning the freezer, allow it to warm up. Allow glass shelves to warm up before immersing in warm water.
Note: See page 7 for specific cleaning instructions for the ClimateZone™ storage drawers and compartment assemblies (select models).
Cleaning Under the Refrigerator
Your refrigerator can be rolled out for cleaning the floor underneath. Raise the leveling feet if engaged (see page 2). Pull the refrigerator straight out from the wall.
No Clean™ Commercial-Duty Condenser
A clean condenser means more efficient refrigerator operation. Thanks to the unique design of the No CleanTM condenser, there’s no longer a need for routine condenser cleaning in normal home usage surroundings.
Some operating environments may be particularly dusty or greasy. In these situations, the condenser can be periodically cleaned to ensure maximum efficiency.
13