AccessIT
132
22. Technical Specifications
Operating systems
Target Server
DOS, Windows, Novell, Linux, SUN Solaris for PC
Client Computer
Windows 2000 and later with Internet Explorer 6 and later or Firefox 3
and later
Linux x86 and Firefox 3 and later
Authentication Local or Microsoft Active Directory
Security SSL, high grade 256-bit AES encryption
Maximum # of users 20
Maximum # of IP devices 50
Maximum # of targets 250 (servers and network devices)
Replication unit Yes
Backup / Restore Yes
Device configuration Automatic discovery of Minicom IP KVM devices
Firmware upgrade Yes
Protocols HTTPS, XML, SSH, Telnet, LDAP
Form factor 1U x 19” rack mountable
Network connection RJ45
Power supply 115-230 VAC, 50-60Hz autosensing
Environmental
Temperature Operating 10° to 35°C (50° to 95°F)
Storage –40° to 65°C (–40° to 149°F)
Relative humidity Operating 20% to 80% (non-condensing) with a maximum humidity
gradation of 10% per hour
Storage 5% to 95% (non-condensing)
Maximum vibration Operating 0.26 Grms at 5–350 Hz for 15 min
Storage 1.54 Grms at 10–250 Hz for 15 min
Maximum shock Operating One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for up to 2.6 ms
Storage Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) of 71
G for up to 2 ms
Altitude Operating –16 to 3,048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2,950 feet, the maximum operating
temperature is derated 1°F/550 ft.
Storage –16 to 10,600 m (–50 to 35,000 ft)
Airborne contaminant
level
Class G2 or lower as defined by ISA-S71.04-1985