<RECORD SETTINGS>

Settings concerning normal recording and alarm recording

This unit allows per camera independent settings for nor- mal recording and alarm recording. By this, more detailed settings are possible such as changing the recording inter- vals of the camera inputting the alarm signals while main- taining the normal recording settings of normal cameras.

Certain settings and mode changes are limited during Alarm recording. Pressing the ALARM INTER- RUPT button halts additional alarm inputs, and stops recording.

During recording, the setting in the <RECORD SETTING> screen cannot be changed.

When the cameras for recording has no input video signal, a warning display of “NO SIGNAL” ap-

pears (for details, see “Warnings and CALL OUT output” pages 96, 97).

Recording mode settings for normal recording and alarm recording

Setting of the camera number for normal recording and alarm recording, the TRIGGER for alarm recording, the recording in- tervals and recording picture quality for normal recording and alarm recording and whether to perform pre-alarm recording for alarm recording can be set here (for normal recording, see “Basic manual recording” pages 27, 28). Pre-alarm record- ing is a function to start recording before the ALARM IN termi- nal on the rear of the unit is grounded or motion is detected (for

details concerning pre-alarm recording, see page 72).

<RECORD SETTINGS>

 

>>ALARM SETTING

 

RECORD SETTING

5S

ALARM REC DURATION

MOTION DET REC

ALARM

ARCHIVE OVERWRITE

OFF

ARCHIVE MEDIA AUTO EJECT

OFF

1.Press the SET UP button } <SETTINGS> } Select “ALARM SETTING” in the <RECORD SETTINGS> screen and turn the SHUTTLE ring clockwise.

The <ALARM SETTING> screen appears.

<ALARM SETTING> 1/2

<ALARM SETTING>

TRIGGER

ALARM

RECORD CAMERA

>>1

1 ---------------

EXT

2

-2--------------

EXT

3

-- 3 -------------

EXT

4

---4------------

EXT

5

----5-----------

EXT

6

-----

6 ----------

EXT

7

------

7 ---------

EXT

8

-------

8 --------

EXT

9

--------

9 -------

EXT

NEXT PAGE

SHUTTLE<<:BACK

<ALARM SETTING> 2/2

<ALARM SETTING>

TRIGGER

ALARM

RECORD CAMERA

>>10

---------10------

EXT

11

----------11-----

EXT

12

-----------12----

EXT

13

------------13---

EXT

14

-------------14--

EXT

15

--------------15-

EXT

16

---------------16

EXT

EMR

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

 

SHUTTLE<<:BACK

The <ALARM SETTING> screen consists of 2 pages. The second page is displayed by turning the JOG dial to move the cursor to “NEXT PAGE”, and turn the SHUTTLE ring clockwise.

2.(When setting the alarm recording camera and trigger • • • ) Turn the JOG dial to select the desired alarm camera channel number and turn the SHUTTLE ring clockwise.

The first item from the left side in the “ALARM RECORD CAMERA” setting display reverses in color.

The camera numbers are lined in order of the number from

“ 1 ” to “ 16 ”.

• Multiple cameras can be entered to record when trigger.

When you turn the JOG dial counterclockwise, the camera number setting or the TRIGGER setting will reverses in color in order such as 1 , EXT, 16 , 15 • • • .

3.Turn the JOG dial to display the desired camera number reversed in color and turn the SHUTTLE ring clockwise.

The background of setting turns red and flashes.

While the setting is flashing, the setting screen can- not be exited even when pressing the SET UP button.

4.Turn the JOG dial to display the desired setting and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops. Multiple camera numbers can be selected for one alarm camera channel number.

5.Turn the JOG dial clockwise to display “TRIGGER” setting reversed in color and turn the SHUTTLE ring clockwise.

The background of setting turns red and flashes.

6.Turn the JOG dial to display the desired setting and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

Setting of “TRIGGER” ( default : “EXT” )

EXT” : Alarm recording can only be started when the ALARM IN terminal is grounded.

“MD&EXT” : Alarm recording can be started when the ALARM IN terminal is grounded and the motion is detected simultaneously.

“MD/EXT” : When the ALARM IN terminal is grounded or motion is detected alarm recording is started.

“MD” : Alarm recording can only be started when the motion is detected.

When you select and set the “TRIGGER” setting to MD, MD/EXT or MD&EXT, the motion detection function will be active and any setting changes can not be accepted. Please use the ALARM INTER- RUPT button to change the setting.

7.When the setting is complete, turn the SHUTTLE ring counterclockwise.

The cursor moves to the camera number on the left.

When continuing with other camera number settings, turn the JOG dial to move the cursor to the desired camera number and repeat steps 2 ~ 7 to perform the settings.

8.(When setting the camera selection during alarm recording • • • ) Press the SET UP button } <SETTINGS> } Select “RECORD SETTING” in the <RECORD SETTINGS> screen and turn the SHUTTLE ring clockwise.

The <RECORD SETTING> screen appears.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

47

Page 47
Image 47
Mitsubishi Electronics DX-TL2500U Settings concerning normal recording and alarm recording, Alarm Setting 1/2